Parmeggiani U, Avenia N, De Falco M, Parmeggiani D, Pisaniello D, d'Ajello M, Monacelli M, Calzolari F, Sanguinetti A, Sperlongano P
V Divisione di Chirurgia Generale e Techniche Chirurgiche Speciali, Dipartimento de Scienze Anestesiologiche, Chirurgiche e delle Emergenze, Seconda Università degli Studi di Napoli.
G Chir. 2005 Oct;26(10):387-94.
In the present study the Authors tried and assess the advantages of the standard sutureless thyroidectomy performed by the Ligasure Vessel Sealing System, thanks to the use of the dedicated Precise handle. The Authors compared the efficacy of haemostasis and the economical impact of the device, in terms of drug administration and costs. The Authors comparatively analyzed 120 total extracapsular thyroidectomies (TET) performed by the standard operative technique (Group A, control) and 70 TET achieved by the "sutureless technique" (Group B, case). There was a statistically significant decrease of transient postoperative hypocalcemia (5.71% vs 7.5%) and also of mean operative time (about 20 minutes) in patients of the group B. Non significant decrease of other kind of complications (postoperative hemorrhage, transient and permanent inferior laryngeal palsy, stupor of the superior laryngeal nerve, seromas) were also observed. The use of the Ligasure Precise resulted easy, safe and efficient in the Authors' experience. It allowed the decrease of postoperative haemorrhages and mean operative time.
在本研究中,作者尝试并评估了使用Ligasure血管闭合系统并借助专用的Precise手柄进行标准无缝合甲状腺切除术的优势。作者从药物使用和成本方面比较了止血效果和该设备的经济影响。作者对采用标准手术技术进行的120例全甲状腺囊外切除术(TET)(A组,对照组)和通过“无缝合技术”完成的70例TET(B组,病例组)进行了对比分析。B组患者术后短暂性低钙血症发生率(5.71%对7.5%)以及平均手术时间(约20分钟)均有统计学意义的下降。还观察到其他类型并发症(术后出血、短暂性和永久性喉返神经麻痹、喉上神经麻痹、血清肿)有非显著性下降。根据作者的经验,使用Ligasure Precise简便、安全且高效。它能减少术后出血和平均手术时间。