Mullins R C, Drez D J
Louisiana State University, Department of Orthopaedics, Lake Charles.
Arthroscopy. 1992;8(2):267-8. doi: 10.1016/0749-8063(92)90049-h.
This article describes a simple technique for the use of a #66 Beaver blade to assist in the resection of bucket-handle meniscus tears. This is a standard ophthalmologic blade and should be readily available in most operating rooms. The technique described is a simple, inexpensive means of resecting bucket-handle tears without changing portals during the procedure.
本文介绍了一种使用#66 比弗刀片辅助切除桶柄状半月板撕裂的简单技术。这是一种标准的眼科刀片,在大多数手术室中应很容易获得。所描述的技术是一种简单、廉价的切除桶柄状撕裂的方法,在手术过程中无需改变入路。