Suppr超能文献

[从中心静脉导管和外周静脉穿刺采集的血培养污染情况。75对样本的前瞻性研究]

[Contamination of blood cultures drawn from central vein catheter and peripheral venipuncture. Prospective study of 75 pairs].

作者信息

Kallel H, Dammak H, Mahjoubi F, Bahloul M, Turki E, Chelly H, Rekik N, Hammami A, Bouaziz M

机构信息

Service de réanimation médicale, CHU Habib Bourguiba, route El-Ain, km 1, 3029 Sfax, Tunisie.

出版信息

Pathol Biol (Paris). 2006 Feb;54(1):44-8. doi: 10.1016/j.patbio.2005.02.006.

Abstract

OBJECTIVE

To determine the frequency of contamination, the sensitivity, specificity, and predictive values of cultures done with blood drawn through a central venous catheter or peripheral venipuncture.

DESIGN

Prospective cohort study of critical ill medical surgical intensive care patients in whom samples for paired culture were drawn through a central venous catheter or peripheral venipuncture during a period of 8 months (from August 1st 2001 to Mars 31st 2002).

RESULTS

During the study period, 75-paired cultures were studied. Fifteen peripheral blood cultures (20%) and 27 central blood cultures (36%) were positive and 6 peripheral blood cultures (8%) and 15 central blood cultures (20%) were contaminated (P=0.034). The organism most commonly responsible for contamination was Coagulase Negative Staphylococcus (16% of central blood cultures and 6.7% of peripheral blood cultures). The frequency of contamination was of 42.9% for blood cultures drawn through a femoral central venous catheter, of 10% for jugular, and of 19% for subclavian central venous catheter (P=0.22). For catheter draws compared with peripheral venipuncture, sensitivity was 100 and 75%, specificity was 76.2 and 90.5%, positive predictive value was 44.4 and 60% and negative predictive value was 100 and 95%.

CONCLUSION

Cultures of blood drawn through a catheter are more sensible and less specific than those obtained from a peripheral venipuncture and the organism most commonly responsible for contamination of blood cultures is Coagulase Negative Staphylococcus.

摘要

目的

确定通过中心静脉导管或外周静脉穿刺采血进行培养的污染频率、敏感性、特异性和预测值。

设计

对危重症内科和外科重症监护患者进行前瞻性队列研究,在8个月期间(从2001年8月1日至2002年3月31日)通过中心静脉导管或外周静脉穿刺采集配对培养样本。

结果

在研究期间,对75对培养样本进行了研究。15份外周血培养(20%)和27份中心血培养(36%)呈阳性,6份外周血培养(8%)和15份中心血培养(20%)被污染(P = 0.034)。最常见的污染菌是凝固酶阴性葡萄球菌(中心血培养的16%和外周血培养的6.7%)。通过股静脉中心静脉导管采血的培养污染频率为42.9%,颈内静脉为10%,锁骨下中心静脉导管为19%(P = 0.22)。与外周静脉穿刺相比,导管采血的敏感性分别为100%和75%,特异性分别为76.2%和90.5%,阳性预测值分别为44.4%和60%,阴性预测值分别为100%和95%。

结论

通过导管采血进行的培养比外周静脉穿刺获得的培养更敏感但特异性更低,血液培养最常见的污染菌是凝固酶阴性葡萄球菌

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验