Suppr超能文献

解放军“眼镜蛇”气道与独特型喉罩在自主通气期间的比较:一项随机前瞻性研究。

A comparison between the PLA Cobra and the Laryngeal Mask Airway Unique during spontaneous ventilation: a randomized prospective study.

作者信息

Gaitini Luis, Yanovski Boris, Somri Mustafa, Vaida Sonia, Riad Tome, Alfery David

机构信息

Department of Anesthesiology, Bnai Zion Medical Center Faculty of Medicine, Technion Israel Institute of Technology, Haifa, Israel.

出版信息

Anesth Analg. 2006 Feb;102(2):631-6. doi: 10.1213/01.ane.0000189098.57662.d6.

Abstract

The Laryngeal Mask (LMA) Unique and the Cobra Perilaryngeal Airway (PLA) are single-use supraglottic devices. There are no published studies comparing these devices during spontaneous ventilation. We compared the LMA Unique and the Cobra PLA with respect to 1) ventilatory variables during spontaneous ventilation, 2) time to achieve an effective airway, 3) airway intervention requirements, 4) cuff seal pressures, 5) fiberoptic score, and 6) perioperative adverse events. Eighty adult ASA physical status I-II patients undergoing general anesthesia for minor routine surgery were randomly allocated to LMA Unique or PLA Cobra for airway management. No statistically significant differences were found between the devices with respect to inspiratory tidal volume, expiratory tidal volume, end-tidal CO2 concentration, respiratory rate, number and type of airway interventions required with placement, the fiberoptic score, and the incidence of perioperative adverse events. The oropharyngeal leak (seal) pressure was higher for the CobraPLA (27 +/- 7 versus 21 +/- 4 cm H2O; P < 0.001). The oxygen saturation was higher (98.1% +/- 1% versus 97.3% +/- 2%; P = 0.02) in the LMA group. Time of insertion was shorter for LMA (23.7 +/- 2 s versus 26.6 +/- 7 s; P = 0.02) and insertion difficulty was less for LMA (P = 0.03). As these differences were not judged to be clinically important, both devices appear to be effective in establishing an adequate airway in patients who are spontaneously breathing under general anesthesia.

摘要

喉罩独特型(LMA Unique)和眼镜蛇型喉周围气道(Cobra Perilaryngeal Airway,Cobra PLA)是一次性使用的声门上气道装置。目前尚无关于这些装置在自主通气期间进行比较的已发表研究。我们比较了喉罩独特型和眼镜蛇型喉周围气道在以下方面的情况:1)自主通气期间的通气变量;2)建立有效气道的时间;3)气道干预需求;4)套囊密封压力;5)纤维喉镜评分;6)围手术期不良事件。八十例接受小型常规手术全身麻醉的美国麻醉医师协会(ASA)身体状况I-II级成年患者被随机分配使用喉罩独特型或眼镜蛇型喉周围气道进行气道管理。在吸气潮气量、呼气潮气量、呼气末二氧化碳浓度、呼吸频率、放置时所需气道干预的数量和类型、纤维喉镜评分以及围手术期不良事件发生率方面,两种装置之间未发现统计学上的显著差异。眼镜蛇型喉周围气道的口咽漏(密封)压力更高(27±7与21±4 cmH₂O;P<0.001)。喉罩组的氧饱和度更高(98.1%±1%与97.3%±2%;P = 0.02)。喉罩的插入时间更短(23.7±2秒与26.6±7秒;P = 0.02),且喉罩的插入难度更小(P = 0.03)。由于这些差异未被判定为具有临床重要性,因此两种装置在全身麻醉下自主呼吸的患者中建立足够气道方面似乎都有效。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验