Suppr超能文献

用于区域麻醉期间减少热量散失的反光毯。

Reflective blankets used for reduction of heat loss during regional anaesthesia.

作者信息

Hindsholm K B, Bredahl C, Herlevsen P, Kruhøffer P K

机构信息

Department of Anaesthesia, Aalborg City and County Hospital, Denmark.

出版信息

Br J Anaesth. 1992 May;68(5):531-3. doi: 10.1093/bja/68.5.531.

Abstract

We have studied the ability of reflective blankets to reduce net loss of body heat during regional anaesthesia for total hip arthroplasty. Thirty patients were allocated randomly to either the study group (insulated with reflective blankets) or the control group (no reflective blankets). Surgical and operation room draping, theatre temperature and i.v. fluid administration were standardized for all patients. Total body heat was deduced from core temperature (aural canal) and mean skin temperature (four measuring sites). After 2 h of surgery, loss of body heat was reduced significantly in patients wrapped in reflective blankets (26 kJ) compared with those in the control group (95 kJ).

摘要

我们研究了反光毯在全髋关节置换术区域麻醉期间减少身体热量净损失的能力。30例患者被随机分配到研究组(使用反光毯保温)或对照组(不使用反光毯)。所有患者的手术和手术室铺巾、手术间温度及静脉输液均标准化。通过核心温度(耳道)和平均皮肤温度(四个测量部位)推算全身热量。手术2小时后,与对照组患者(95千焦)相比,使用反光毯包裹的患者身体热量损失显著减少(26千焦)。