Fine Jeffrey J, Hopkins Christie B, Ruff Nicol, Newton F Carter
The Department of Investigator Initiated Research, South Carolina Heart Center, Columbia, South Carolina, USA.
Am J Cardiol. 2006 Jan 15;97(2):173-4. doi: 10.1016/j.amjcard.2005.08.021. Epub 2005 Nov 17.
Cardiovascular computed tomography (CVCT) with the recently released 64-slice technology increases spatial resolution and decreases acquisition times and slice thickness. We investigated the accuracy of 64-slice CVCT in relation to catheter angiography. We studied 66 sequential subjects who underwent 64-slice CVCT and catheter angiography within 30 days. Accuracy results were 94% for interpretable images, 95% for sensitivity, 96% for specificity, 97% for positive predictive value, and 92% for negative predictive value for lesions with >50% stenosis. We found 100% agreement between 64-slice CVCT and catheterization among vein graft evaluations (9 of 9). These metrics are vastly improved from the 16-slice generation and support 64-slice CVCT as a reliable diagnostic tool.