Ma Jinyu, Gu Yanli, Chen Bo, Yao Shouzhuo, Chen Zeneng
Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Hunan Normal University), Ministry of Education, Hunan Normal University, Changsha 410081, PR China.
J Chromatogr A. 2006 Apr 28;1113(1-2):55-9. doi: 10.1016/j.chroma.2006.01.114. Epub 2006 Feb 17.
A simple and sensitive HPLC/ESI-MS method for the determination of tiopronin in human plasma was described. Vitamin C and 2-mercaptoethanol (2-Me) were used as the reducer and the stabilitizer to release and stabilify tiopronin from a dimmer and mix forms with endogenous thiols in the treatment of plasma samples. The analytes were separated on a Johnson Spherigel analytical column packed with 5 microm C8 silica, using the formic acid aqueous solution (pH 4.5) including tris(hydroxymethyl) aminomethane (Tris) and 2-Me (0.5 and 1 mM, respectively) as a mobile phase. Cyclamate was used as the internal standard (I.S.) for the quantification of tiopronin. The correlation coefficient of the calibration curve were better than 0.998 in the range of 0.107-5.35 microg/ml in human plasma. The limit of quantification (LOQ) was 0.107 microg/ml (S/N 10:1, RSD 7.1%). The inter-day and intra-day accuracy was below 7.1 and 6.8%, respectively. As a preliminary application, this method has been successfully applied to the determination of tiopronin in the human plasma.
描述了一种用于测定人血浆中硫普罗宁的简单灵敏的高效液相色谱/电喷雾质谱法。在处理血浆样品时,使用维生素C和2-巯基乙醇(2-Me)作为还原剂和稳定剂,以从二聚体和与内源性硫醇的混合形式中释放并稳定硫普罗宁。分析物在填充有5微米C8硅胶的Johnson Spherigel分析柱上分离,使用包含三(羟甲基)氨基甲烷(Tris)和2-Me(分别为0.5和1 mM)的甲酸水溶液(pH 4.5)作为流动相。用环己基氨基磺酸盐作为内标(I.S.)来定量硫普罗宁。人血浆中校准曲线在0.107 - 5.35微克/毫升范围内的相关系数优于0.998。定量限(LOQ)为0.107微克/毫升(信噪比10:1,相对标准偏差7.1%)。日间和日内准确度分别低于7.1%和6.8%。作为初步应用,该方法已成功应用于人血浆中硫普罗宁的测定。