The presence of cuff imbalance degrades the signal-to-interference (ENG/EMG) ratio in tripolar nerve cuff electrode recordings. Known causes of cuff imbalance include inhomogeneous tissue growth after cuff implantation and cuff manufacturing tolerances. In this paper, we report on an additional contribution to cuff imbalance that stems from variations in orientation and distance of the tripolar cuff relative to the external interference source. The latter is represented here by a dipole. Interference amplitude is also shown to depend on orientation and distance variations, here both factors included in the term "proximity." The study was conducted using field simulations and saline-bath experiments.

摘要

袖带失衡的存在会降低三极神经袖带电极记录中的信号干扰(ENG/EMG)比。已知的袖带失衡原因包括袖带植入后组织生长不均匀以及袖带制造公差。在本文中,我们报告了袖带失衡的另一个原因,它源于三极袖带相对于外部干扰源的方向和距离变化。这里外部干扰源由一个偶极表示。干扰幅度也显示取决于方向和距离变化,这里这两个因素都包含在“接近度”这一术语中。该研究通过场模拟和盐水浴实验进行。