A biomechanical comparison of 2 techniques for reconstructing atrophic edentulous mandible fractures.

作者信息

Madsen Matthew J, Haug Richard H

机构信息

College of Dentistry, University of Kentucky, Lexington, KY 40536-0297, USA.

出版信息

J Oral Maxillofac Surg. 2006 Mar;64(3):457-65. doi: 10.1016/j.joms.2005.11.018.

Abstract

OBJECTIVES

The purpose of this investigation was to evaluate and compare the biomechanical behavior of 2 techniques for the reconstruction of atrophic edentulous mandible fractures.

MATERIALS AND METHODS

Thirty polyurethane atrophic edentulous mandible replicas (Sawbones, Vashon Island, WA) were used in this investigation (10 controls, 10 replicas of 2 different fixation techniques). The first reconstruction technique was a traditional titanium locking reconstruction plate affixed to the lateral border (buccal surface) of the mandible. The second reconstruction technique used the same type of plate, but placed it on the inferior border of the mandible. Both constructs were subjected to vertical loading at the symphysis and torsional loading at the body regions of the mandible replicas by an Instron 1331 (Instron, Canton, MA) servohydraulic mechanical testing unit. Mechanical deformation data within a 0-900 N range were recorded. Maximum load, displacement at maximum load, and stiffness were determined. Means and standard deviations were derived and compared for statistical significance using a Fisher's Protected Least Significant Differences Test with a confidence level of 95% (P < .05). Second- and third-order polynomial best-fit curves were also created for each group to further evaluate the mechanical behavior.

RESULTS

For symphysis loading, statistically significant differences were noted between the control group and both of the plating techniques for displacement at maximum load. However, no differences were noted between the experimental groups for displacement at maximum load, stiffness, or maximum load. For body loading, statistically significant differences were noted between the control group and the inferior border plating group for displacement at maximum load. However, no differences were noted between the experimental groups for displacement at maximum load, stiffness, or maximum load.

CONCLUSION

During this bench top investigation, there were no significant differences noted in mechanical behavior between the 2 specific experimental groups for any of the conditions measured. When placed in the context of functional parameters, both of the plating techniques met or exceeded the requirements for loading.

摘要

目的

本研究旨在评估和比较两种用于重建萎缩性无牙下颌骨骨折的技术的生物力学行为。

材料与方法

本研究使用了30个聚氨酯萎缩性无牙下颌骨模型(Sawbones,华盛顿州瓦申岛)(10个对照组,10个采用两种不同固定技术的模型)。第一种重建技术是将传统的钛锁定重建钢板固定在下颌骨的外侧边缘(颊面)。第二种重建技术使用相同类型的钢板,但将其放置在下颌骨的下缘。两种结构均通过Instron 1331(英斯特朗公司,马萨诸塞州坎顿)伺服液压机械测试单元在下颌骨模型的联合处进行垂直加载,并在体部区域进行扭转加载。记录0 - 900 N范围内的机械变形数据。确定最大载荷、最大载荷下的位移和刚度。使用置信水平为95%(P < 0.05)的Fisher保护最小显著差异检验得出均值和标准差并进行比较以确定统计学显著性。还为每组创建了二阶和三阶多项式最佳拟合曲线以进一步评估力学行为。

结果

对于联合处加载,在最大载荷下的位移方面,对照组与两种钢板固定技术组之间存在统计学显著差异。然而,在最大载荷下的位移、刚度或最大载荷方面,实验组之间未发现差异。对于体部加载,在最大载荷下的位移方面,对照组与下缘钢板固定组之间存在统计学显著差异。然而,在最大载荷下的位移、刚度或最大载荷方面,实验组之间未发现差异。

结论

在本次台架研究中,在所测量的任何条件下,两个特定实验组之间的力学行为均未发现显著差异。从功能参数的角度来看,两种钢板固定技术均达到或超过了加载要求。