Suppr超能文献

膝关节磁共振成像的准确性与不必要的手术

Accuracy of magnetic resonance imaging of the knee and unjustified surgery.

作者信息

Ben-Galim Peleg, Steinberg Ely L, Amir Hagai, Ash Nachman, Dekel Shmuel, Arbel Ron

机构信息

Department of Orthopedic Surgery B, Tel-Aviv Sourasky Medical Center, Tel-Aviv, Israel.

出版信息

Clin Orthop Relat Res. 2006 Jun;447:100-4. doi: 10.1097/01.blo.0000203471.50808.b7.

Abstract

Magnetic resonance imaging of the knee is greater than 90% accurate in detecting intraarticular disease when performed and interpreted by musculoskeletal magnetic resonance imaging specialists in specialized medical centers. However, independent imaging institutions often offer less expensive services to health insurers. We wondered if the magnetic resonance imaging performed in our community is of equivalent quality and accuracy. We studied a homogenous group of healthy, young, and fit military recruits to represent a cross section of our country's population. We analyzed all knee magnetic resonance images of soldiers who subsequently had primary arthroscopic knee surgery within a 3-month period from 1997-1998. The results were compared with surgical findings of four structures: medial meniscus, lateral meniscus, anterior cruciate ligament, and articular cartilage. Of the 1185 arthroscopies and 633 magnetic resonance images of the knee performed in 14 institutions, 139 paired magnetic resonance imaging arthroscopic reports met our inclusion criteria. The results showed a false positive rate of 65% for the medial meniscus, 43% for the lateral meniscus, 47.2% for the anterior cruciate ligament, and 41.7% for articular cartilage disease when compared with surgical findings. Accuracy rates were 52%, 82%, 80%, and 77%, respectively. Thirty-seven percent of the operations supported by a significant disorder on magnetic resonance imaging were unjustified. Our findings highlight the consequences that may occur when basing medical care on cost rather than quality of care.

摘要

当由专业医疗中心的肌肉骨骼磁共振成像专家进行操作和解读时,膝关节磁共振成像检测关节内疾病的准确率超过90%。然而,独立的成像机构通常会为健康保险公司提供价格较低的服务。我们想知道我们社区所做的磁共振成像质量和准确性是否相当。我们研究了一组同质的健康、年轻且身体状况良好的新兵,以代表我国人口的一个横断面。我们分析了1997年至1998年3个月内随后接受初次膝关节镜手术的士兵的所有膝关节磁共振图像。将结果与四个结构的手术结果进行比较:内侧半月板、外侧半月板、前交叉韧带和关节软骨。在14个机构进行的1185例关节镜检查和633例膝关节磁共振成像中,139份配对的磁共振成像关节镜检查报告符合我们的纳入标准。与手术结果相比,内侧半月板的假阳性率为65%,外侧半月板为43%,前交叉韧带为47.2%,关节软骨疾病为41.7%。准确率分别为52%、82%、80%和77%。磁共振成像显示有明显疾病支持的手术中有37%是不合理的。我们的研究结果突出了基于成本而非医疗质量进行医疗护理可能产生的后果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验