Trattnig Siegfried, Pinker Kathia, Ba-Ssalamah Ahmed, Nöbauer-Huhmann Iris-Melanie
Center of Excellence High field MRI, Department of Radiology, University Hospital of Vienna, Medical School, Währinger Gürtel 18-20, 1090 Vienna, Austria.
Eur Radiol. 2006 Jun;16(6):1280-7. doi: 10.1007/s00330-006-0154-0. Epub 2006 Mar 1.
The intravenous administration of a standard dose of conventional gadolinium-based contrast agents produces higher contrast between the tumor and normal brain at 3.0 Tesla (T) than at 1.5 T, which allows reducing the dose to half of the standard one to produce similar contrast at 3.0 T compared to 1.5 T. The assessment of cumulative triple-dose 3.0 T images obtained the best results in the detection of brain metastases compared to other sequences. The contrast agent dose for dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging at 3.0 T can be reduced to 0.1 mmol compared to 0.2 mmol at 1.5 T due to the increased susceptibility effects at higher magnetic field strengths. Contrast agent application makes susceptibility-weighted imaging (SWI) at 3.0 T clinically attractive, with an increase in spatial resolution within the same scan time. Whereas a double dose of conventional gadolinium-based contrast agents was optimal in SWI with respect to sensitivity and image quality, a standard dose of gadobenate dimeglumine, which has a two-fold higher T1-relaxivity in blood, produced the same effect. For MR-arthrography, optimized concentrations of gadolinium-based contrast agents are similar at 3.0 and 1.5 T. In summary, high field MRI requires the optimization of the contrast agent dose in different clinical applications.
在3.0特斯拉(T)磁场下静脉注射标准剂量的传统钆基造影剂,肿瘤与正常脑之间产生的对比度高于1.5 T时,这使得在3.0 T时可将剂量减半就能产生与1.5 T时相似的对比度。与其他序列相比,评估累积三倍剂量的3.0 T图像在检测脑转移瘤方面取得了最佳结果。由于在更高磁场强度下敏感性增加,3.0 T时动态磁敏感加权对比增强灌注磁共振成像的造影剂剂量可从1.5 T时的0.2 mmol降至0.1 mmol。造影剂的应用使3.0 T时的磁敏感加权成像(SWI)在临床上具有吸引力,在相同扫描时间内提高了空间分辨率。就敏感性和图像质量而言,双倍剂量的传统钆基造影剂在SWI中是最佳的,而钆贝葡胺标准剂量在血液中的T1弛豫率高出两倍,却产生了相同效果。对于磁共振关节造影,钆基造影剂的优化浓度在3.0 T和1.5 T时相似。总之,高场强磁共振成像在不同临床应用中需要优化造影剂剂量。