Al-Jarallah M I
Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia.
Radiat Prot Dosimetry. 2006;121(3):293-6. doi: 10.1093/rpd/ncl023. Epub 2006 Mar 17.
Indoor radon concentration measurement in the dwellings of Al-Jauf region of Saudi Arabia was carried out using passive radon dosemeters. The objective of this radon survey was to obtain representative indoor radon data of Al-Jauf region. The study is a continuation of radon survey in main cities of Saudi Arabia which constitutes a baseline for Saudi Arabia in the Radon World Atlas. A total of 318 passive radon dosemeters were distributed randomly in the region and placed for a period of 1 y starting from April 2004 to April 2005. The results of indoor radon concentration measurement in 136 dwellings distributed in Al-Jauf region are presented. The remaining dosemeters were lost in the dwellings or mishandled. The results showed that the average, minimum, maximum radon concentrations and standard deviation were 35, 7, 168 and 30 Bq m(-3), respectively. Geometric mean and geometric standard deviation of the radon distribution were found to be 28 and 1.83, respectively.
利用被动式氡剂量计对沙特阿拉伯焦夫地区住宅内的氡浓度进行了测量。此次氡调查的目的是获取焦夫地区具有代表性的室内氡数据。该研究是沙特阿拉伯主要城市氡调查的延续,为《氡世界地图集》中的沙特阿拉伯建立了一个基线。总共318个被动式氡剂量计被随机分发到该地区,并从2004年4月至2005年4月放置了1年时间。文中给出了焦夫地区136处住宅内氡浓度的测量结果。其余剂量计在住宅内丢失或被不当处理。结果显示,氡浓度的平均值、最小值、最大值和标准差分别为35、7、168和30 Bq m(-3)。氡分布的几何平均值和几何标准差分别为28和1.83。