Vámosi Péter, Nemeth Gabor, Berta Andras
Department of Ophthalmology, Medical and Health Science Center, University of Debrecen, Debrecen, Hungary.
J Cataract Refract Surg. 2006 Feb;32(2):221-6. doi: 10.1016/j.jcrs.2005.08.059.
To evaluate the amplitude of pseudophakic accommodation of 2 foldable intraocular lenses (IOLs) by measuring the anterior chamber depth (ACD) shift during a 1-year follow-up.
Department of Ophthalmology, Medical and Health Science Center, University of Debrecen, Debrecen, Hungary.
This prospective study comprised 44 eyes of 44 cataract patients operated on with phacoemulsification and in-the-bag implantation of Akreos Disc (22 eyes) or AcrySof MA60BM (22 eyes) IOLs. The ACD was measured by A-scan during fixation at 30 cm and again after instillation of cyclopentolate 1%. The ACD shift was calculated by subtracting the ACD under cyclopentolate from the ACD during fixation at 30 cm. Follow-up measurements were performed 3, 6, and 12 months after surgery. Statistical analysis concerning the difference between the 2 groups was done by the Student unpaired t test.
The ACD shift was greater in the AcrySof group than in the Akreos Disc group at all 3 follow-up examinations. The difference was highly significant between the 2 groups at 6 and 12 months (both P = .004). After the operation, the ACD shift increased continuously with time in both groups. The mean ACD shift reached 0.57 mm +/- 0.25 (SD) in the AcrySof group and 0.42 +/- 0.24 mm in the Akreos group at 12 months.
The 3-piece AcrySof MA60BM IOL with 10-degree posterior angulation had a significantly higher capacity for pseudophakic accommodation than the 1-piece plate-haptic Akreos Disc IOL. The continuous increase in the ACD shift in the postoperative period may mean that patients learn to achieve better accommodation with an IOL as time goes on.
通过测量1年随访期间前房深度(ACD)的变化,评估2种可折叠人工晶状体(IOL)的假晶状体调节幅度。
匈牙利德布勒森大学医学与健康科学中心眼科。
本前瞻性研究纳入44例白内障患者的44只眼,这些患者接受了超声乳化白内障吸除术并在囊袋内植入Akreos Disc(22只眼)或AcrySof MA60BM(22只眼)IOL。在30 cm注视时通过A超测量ACD,然后滴入1%环喷托酯后再次测量。通过用30 cm注视时的ACD减去滴入环喷托酯后的ACD来计算ACD变化。术后3、6和12个月进行随访测量。采用Student非配对t检验对两组间差异进行统计学分析。
在所有3次随访检查中,AcrySof组的ACD变化均大于Akreos Disc组。两组在6个月和12个月时差异具有高度显著性(均P = .004)。术后,两组的ACD变化均随时间持续增加。12个月时,AcrySof组的平均ACD变化达到0.57 mm±0.25(标准差),Akreos组为0.42±0.24 mm。
具有10度后倾角的三片式AcrySof MA60BM IOL的假晶状体调节能力明显高于一片式板袢Akreos Disc IOL。术后ACD变化的持续增加可能意味着随着时间推移患者学会了更好地使用IOL进行调节。