一种新型设计的后房人工晶状体(囊袋内植入型晶状体)在老视眼中调节力的个体内随机对照研究。

A randomized intraindividual comparison of the accommodative performance of the bag-in-the-lens intraocular lens in presbyopic eyes.

机构信息

Department of Ophthalmology, St. Thomas' Hospital, London, United Kingdom.

出版信息

Am J Ophthalmol. 2010 Nov;150(5):619-627.e1. doi: 10.1016/j.ajo.2010.06.003. Epub 2010 Aug 16.

Abstract

PURPOSE

To compare the accommodative performance of the Morcher BioComFold Type 89A bag-in-the-lens intraocular lens (IOL) with a conventional in-the-bag control IOL in presbyopic eyes.

DESIGN

Prospective, randomized clinical trial with intraindividual comparison.

SETTING

Department of Ophthalmology, St. Thomas' Hospital, London, United Kingdom.

STUDY POPULATION

Fifty-two eyes of 26 patients with bilateral age-related cataracts.

INTERVENTION

Phacoemulsification cataract extraction with implantation of a bag-in-the-Lens and a control IOL, the Alcon AcrySof SA60AT (Alcon Laboratories, Fort Worth, Texas, USA), randomized to either eye.

MAIN OUTCOME MEASURES

Axial IOL shift stimulated by physiologic (near visual effort) and pharmacologic (pilocarpine and cyclopentolate) accommodative stimulation was measured objectively with partial coherence interferometry. Other outcome measures were objective and subjective accommodation, logarithm of the minimal angle of resolution distance-corrected near visual acuity, and defocus curves.

RESULTS

Three months after surgery, axial IOL shift stimulated by near visual effort measured -5.9 ± 10.3 μm in bag-in-the-lens eyes versus -8.4 ± 12.8 μm in control eyes (P = .37), that stimulated by pilocarpine measured 20.2 ± 165.6 μm versus 50.4 ± 164.4 μm (P = .36), and that stimulated by cyclopentolate measured -65.8 ± 64.3 μm versus -54.0 ± 37.5 μm (P = .34), respectively (n = 25). Objective accommodation measured 0.03 ± 0.18 diopters (D) in bag-in-the-lens eyes versus 0.08 ± 0.21 D in control eyes (P = .40), whereas subjective accommodation measured 2.48 ± 0.72 D versus 2.45 ± 0.80 D (P = .75), respectively. Distance-corrected near visual acuity and defocus curves showed no difference between IOLs.

CONCLUSIONS

The bag-in-the-lens IOL demonstrated negligible axial shift and objective accommodation with physiologic near visual stimulation. The IOL shift demonstrated with pilocarpine also was clinically insignificant. The bag-in-the-lens IOL showed no accommodative or near visual advantage over a conventional in-the-bag IOL, despite its unique capsular fixation method. This provides further evidence that the focus-shift principle fails to produce clinically significant IOL movement.

摘要

目的

比较 Morcher BioComFold Type 89A 注人式襻型人工晶状体(IOL)与常规囊袋内 IOL 在老视眼中的调节性能。

设计

前瞻性、随机临床试验,个体内对照。

地点

英国伦敦圣托马斯医院眼科。

研究人群

52 只眼,26 例双侧年龄相关性白内障患者。

干预

超声乳化白内障吸除术联合注人式襻型和对照型 IOL(美国爱尔康公司的 AcrySof SA60AT)植入,随机植入一眼。

主要观察指标

应用部分相干干涉仪客观测量生理性(近视力努力)和药理学(毛果芸香碱和环戊通)调节刺激引起的轴向 IOL 移位。其他观察指标包括客观和主观调节、最小分辨角距离校正近视力对数、散焦曲线。

结果

术后 3 个月,近视力努力刺激下,注人式襻型眼的轴向 IOL 移位为-5.9±10.3μm,对照眼为-8.4±12.8μm(P=0.37);毛果芸香碱刺激下,注人式襻型眼的轴向 IOL 移位为 20.2±165.6μm,对照眼为 50.4±164.4μm(P=0.36);环戊通刺激下,注人式襻型眼的轴向 IOL 移位为-65.8±64.3μm,对照眼为-54.0±37.5μm(P=0.34)(n=25)。注人式襻型眼的客观调节为 0.03±0.18 屈光度(D),对照眼为 0.08±0.21 D(P=0.40);主观调节分别为 2.48±0.72 D 和 2.45±0.80 D(P=0.75)。IOL 远近视力矫正和散焦曲线无差异。

结论

注人式襻型 IOL 对生理性近视力刺激表现出可忽略的轴向移位和客观调节。毛果芸香碱刺激下的 IOL 移位也无临床意义。尽管注人式襻型 IOL 有其独特的囊袋固定方式,但在调节和近视力方面与常规囊袋内 IOL 无差异。这进一步证明焦点移位原理无法产生有临床意义的 IOL 运动。