Rauh Manfred, Gröschl Michael, Rascher Wolfgang, Dörr Helmuth G
Klinik für Kinder und Jugendliche, Universitätsklinikum Erlangen, Loschgestr. 15, 91054 Erlangen, Germany.
Steroids. 2006 Jun;71(6):450-8. doi: 10.1016/j.steroids.2006.01.015. Epub 2006 Mar 29.
Plasma 17 alpha-hydroxyprogesterone (17-OHP), androstenedione and testosterone measurements are important for the diagnosis and monitoring of hyperandrogenic disorders, most importantly for congenital adrenal hyperplasia (CAH) due to 21-hydroxylase deficiency. The reliability of immunoassays has proved questionable especially for newborns and children. In order to reduce the analytical interferences due to cross-reactivity or matrix effects, to improve accuracy and shorten the analysis time, we have developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method with atmospheric pressure chemical ionization (APCI) for simultaneous measurement. An on-line extraction cartridge with column-switching technique and liquid chromatography over a Chromolith RP 18 e column allow a rapid and easy quantification. The lowest limit of detection was 0.03-0.06 microg/L. Our method has proved linear up to 250 microg/L (r=0.999). Recoveries (S.D.) of 17-OHP, androstenedione and testosterone in plasma were 100% (5), 102% (2) and 92% (4), respectively. The regression equation for the LC-MS/MS (x) and immunoassay (y) methods for 17-OHP (excluding neonate samples) was y=1.942 x+0.255 nmol/L (r=0.695; n=97). In comparison to our values, the immunoassay generally overestimates steroid concentration. The regression equation for the LC-MS/MS (x) and immunoassay (y) methods for testosterone was y=0.963 x+0.035 nmol/L (r=0.955; n=107). Preliminary reference intervals for children were determined as a function of age and sex. The sensitivity and specificity of the LC-MS/MS method offer advantages over routine immunoassays due to the elimination of interferences especially for newborns, high throughput and short chromatographic run time.
血浆17α-羟孕酮(17-OHP)、雄烯二酮和睾酮的测定对于诊断和监测高雄激素血症性疾病非常重要,对于因21-羟化酶缺乏导致的先天性肾上腺皮质增生症(CAH)尤为重要。免疫测定的可靠性已被证明存在疑问,尤其是对于新生儿和儿童。为了减少由于交叉反应或基质效应引起的分析干扰,提高准确性并缩短分析时间,我们开发了一种采用大气压化学电离(APCI)的液相色谱-串联质谱(LC-MS/MS)方法用于同时测定。带有柱切换技术的在线萃取柱和在Chromolith RP 18 e柱上的液相色谱实现了快速简便的定量。最低检测限为0.03 - 0.06μg/L。我们的方法在高达250μg/L时已证明呈线性(r = 0.999)。血浆中17-OHP、雄烯二酮和睾酮的回收率(标准差)分别为100%(5)、102%(2)和92%(4)。17-OHP(不包括新生儿样本)的LC-MS/MS(x)和免疫测定(y)方法的回归方程为y = 1.942x + 0.255 nmol/L(r = 0.695;n = 97)。与我们的值相比,免疫测定通常高估了类固醇浓度。睾酮的LC-MS/MS(x)和免疫测定(y)方法的回归方程为y = 0.963x + 0.035 nmol/L(r = 0.955;n = 107)。根据年龄和性别确定了儿童的初步参考区间。由于消除了干扰,特别是对于新生儿,具有高通量和较短的色谱运行时间,LC-MS/MS方法的灵敏度和特异性优于常规免疫测定。