Uematsu Mikio, Kurosawa Masahiko
Plant and System Planning Department, Toshiba Corporation, Shinsugita-cho 8, Isogo-ku, Yokohama 235-8523, Japan.
Radiat Prot Dosimetry. 2005;116(1-4 Pt 2):534-7. doi: 10.1093/rpd/nci238.
A generalised and convenient skyshine dose analysis method has been developed based on forward-adjoint folding technique. In the method, the air penetration data were prepared by performing an adjoint DOT3.5 calculation with cylindrical air-over-ground geometry having an adjoint point source (importance of unit flux to dose rate at detection point) in the centre. The accuracy of the present method was certified by comparing with DOT3.5 forward calculation. The adjoint flux data can be used as generalised radiation skyshine data for all sorts of nuclear facilities. Moreover, the present method supplies plenty of energy-angular dependent contribution flux data, which will be useful for detailed shielding design of facilities.
基于正向-伴随折叠技术,开发了一种通用且便捷的天空反散射剂量分析方法。在该方法中,通过使用中心具有伴随点源(单位通量对探测点剂量率的重要性)的圆柱形地面上空空气几何结构进行伴随DOT3.5计算来准备空气穿透数据。通过与DOT3.5正向计算进行比较,验证了本方法的准确性。伴随通量数据可作为各类核设施的通用辐射天空反散射数据。此外,本方法提供了大量能量-角度相关的贡献通量数据,这将有助于设施的详细屏蔽设计。