PURPOSE

We evaluated the clinical usefulness of flicker perimetry in glaucoma and glaucoma suspect patients using the new Octopus 311 automated perimeter.

METHODS

A total of 52 eyes of 52 glaucoma patients, 26 eyes of 26 glaucoma suspect patients and 61 eyes of 61 normal subjects were examined using standard automated perimetry (SAP), flicker perimetry and frequency doubling technology (FDT) perimetry. Flicker perimetry was performed using the Octopus 311 and its remote software package. Suprathreshold four-zone probability strategy was used to classify the critical fusion frequency probability level. The classified levels were set at 5% and 1% of probability of normality and 5 Hz. Frequency doubling technology perimetry was performed using 24-2-5, 24-2-1, N-30-5, N-30-1 screening programs using Humphrey Matrix perimetry. Standard automated perimetry was performed using the Humphrey field analyser program 24-2 full threshold. Optical coherence tomography using Stratus OCT was used for evaluating the retinal nerve fibre layer thickness in all glaucoma and glaucoma suspect patients.

RESULTS

Receiver operating characteristic (ROC) curves were calculated. In the early stage of glaucoma, the areas under the ROC curve (AUCs) were 0.96 in flicker and 0.90 in Matrix perimetry. In the moderate and advanced stages of glaucoma, the AUCs were almost 1.0 in all tests. In glaucoma suspect patients, the AUC of the 5% probability level in flicker was significantly higher than in Matrix perimetry.

CONCLUSION

The four-zone probability strategy using the Octopus 311 is a useful method for evaluating the flicker field in early glaucoma and glaucoma suspect patients.

摘要

目的

我们使用新型Octopus 311自动视野计评估了闪烁视野检查在青光眼及青光眼可疑患者中的临床实用性。

方法

对52例青光眼患者的52只眼、26例青光眼可疑患者的26只眼以及61例正常受试者的61只眼进行了标准自动视野检查(SAP)、闪烁视野检查和倍频技术(FDT)视野检查。使用Octopus 311及其远程软件包进行闪烁视野检查。采用超阈值四区概率策略对临界融合频率概率水平进行分类。分类水平设定为正常概率的5%和1%以及5赫兹。使用Humphrey Matrix视野计的24-2-5、24-2-1、N-30-5、N-30-1筛查程序进行倍频技术视野检查。使用Humphrey视野分析仪程序24-2全阈值进行标准自动视野检查。使用Stratus OCT光学相干断层扫描评估所有青光眼和青光眼可疑患者的视网膜神经纤维层厚度。

结果

计算了受试者操作特征(ROC)曲线。在青光眼早期,闪烁视野检查的ROC曲线下面积(AUC)为0.96,Matrix视野检查为0.90。在青光眼的中度和晚期,所有检查的AUC几乎均为1.0。在青光眼可疑患者中,闪烁视野检查5%概率水平的AUC显著高于Matrix视野检查。

结论

使用Octopus 311的四区概率策略是评估早期青光眼和青光眼可疑患者闪烁视野的一种有用方法。