Suppr超能文献

一项为期十年的研究,比较酶联免疫吸附测定法与免疫荧光抗体检测法在检测猫白血病病毒感染方面的效果。

Ten-year study comparing enzyme-linked immunosorbent assay with the immunofluorescent antibody test for detection of feline leukemia virus infection in cats.

作者信息

Hardy W D, Zuckerman E E

机构信息

Laboratory of Veterinary Oncology, Memorial Sloan Kettering Cancer Center, New York, NY 10021.

出版信息

J Am Vet Med Assoc. 1991 Nov 15;199(10):1365-73.

PMID:1666084
Abstract

Immunodetection tests for feline retroviruses are powerful tools used in modern veterinary practice. Veterinarians must fully understand the characteristics--strengths and weaknesses--of the FeLV tests so that the information gained from them can be used properly. Any FeLV ELISA or immunofluorescent antibody (IFA) test is a method for detection of FeLV infection (the virus) and is not a diagnostic test for leukemia or other feline disease. From previous studies, it was determined that the most accurate test for detection of persistent FeLV infection is the IFA test, which detects FeLV antigens in cytoplasm of leukocytes in the blood of infected cats. In the study reported here, 1,142,600 FeLV IFA tests were performed between June 1972 and December 1990. During this period 19.8% of the IFA test results were positive and 78% were negative. Evaluation was not possible for the remaining 2.2% of the tests because of lack of enough leukocytes in the smears to evaluate, or nonspecific staining reactions. In 1979, 7 years after introduction of the IFA test, in-hospital FeLV ELISA were introduced, which enabled veterinarians to test for FeLV in their hospitals. Ever since that time, continual discrepancies have been reported between results of FeLV ELISA and IFA tests, particularly between positive ELISA results and their IFA test confirmation. A 10-year comparison was made between practitioner-performed in-hospital FeLV ELISA (n = 20, 240 tests) results and FeLV IFA test performed by a commercial laboratory. All samples tested by ELISA were submitted (for confirmation of results) by veterinarians from the United States, Canada, Europe, Japan, and Australia.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

猫逆转录病毒的免疫检测试验是现代兽医实践中使用的有力工具。兽医必须充分了解猫白血病病毒(FeLV)检测的特点——优点和缺点——以便能正确利用从中获得的信息。任何FeLV酶联免疫吸附测定(ELISA)或免疫荧光抗体(IFA)检测都是检测FeLV感染(病毒)的方法,而不是白血病或其他猫科疾病的诊断试验。根据先前的研究,确定检测持续性FeLV感染最准确的试验是IFA试验,该试验可检测受感染猫血液中白细胞细胞质中的FeLV抗原。在本文报道的研究中,1972年6月至1990年12月期间共进行了1142600次FeLV IFA检测。在此期间,19.8%的IFA检测结果为阳性,78%为阴性。由于涂片中有足够的白细胞可供评估,或存在非特异性染色反应,其余2.2%的检测无法进行评估。1979年,在引入IFA检测7年后,医院内开始使用FeLV ELISA,这使兽医能够在其医院检测FeLV。从那时起,不断有报道称FeLV ELISA和IFA检测结果之间存在差异,特别是ELISA阳性结果与其IFA检测确认结果之间的差异。对从业者在医院进行的FeLV ELISA(n = 20240次检测)结果与商业实验室进行的FeLV IFA检测结果进行了为期10年的比较。所有通过ELISA检测的样本均由来自美国、加拿大、欧洲、日本和澳大利亚的兽医提交(用于结果确认)。(摘要截短为250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验