Lim Taehyung, Yang Sungjae, Kim Myoungjoon, Tchah Hungwon
Department of Ophthalmology, University of Ulsan College of Medicine, Asan Medical Center, 388-1 Pungnap-dong, Songpa-gu, Seoul 138-736, Korea.
Am J Ophthalmol. 2006 May;141(5):833-9. doi: 10.1016/j.ajo.2005.12.032.
To compare clinical outcomes between the IntraLase femtosecond laser and the mechanical microkeratome for creating flaps during laser in situ keratomileusis.
Nonrandomized clinical trial.
The study involved a total of 55 eyes of 30 patients, with 27 eyes of 16 patients comprising the microkeratome group and 28 eyes of 14 patients comprising the IntraLase group. Refractive errors, visual acuity, higher-order aberrations, contrast sensitivity, and corneal sensitivity were compared between the two groups.
There were no statistically significant differences between the two groups in terms of refractive errors and postoperative uncorrected visual acuity. There was no loss of best-corrected visual acuity in either group. The higher-order aberrations were similar in both groups (P > .05), except for spherical aberration, which was greater in the microkeratome group (P < .05). In the IntraLase group, the contrast sensitivity value at 12 and 18 cycles per degree under mesopic conditions was significantly improved at three months postoperatively (P < .05). The IntraLase group showed faster corneal sensitivity recovery compared with the microkeratome group, and corneal sensitivity in the peripheral area was nearly normalized at three months postoperatively in the IntraLase group.
The femtosecond laser may have advantages over the microkeratome in the flap-making procedure. However, the IntraLase femtosecond laser failed to have significant superiority over the mechanical microkeratome in clinical outcomes, except for faster recovery of corneal sensation, lesser degree of spherical aberration, and some contrast sensitivity value.
比较在准分子原位角膜磨镶术(LASIK)中使用飞秒激光制瓣和机械微型角膜刀制瓣的临床效果。
非随机临床试验。
该研究共纳入30例患者的55只眼,其中16例患者的27只眼组成微型角膜刀组,14例患者的28只眼组成飞秒激光组。比较两组的屈光不正、视力、高阶像差、对比敏感度和角膜敏感度。
两组在屈光不正和术后未矫正视力方面无统计学显著差异。两组均未出现最佳矫正视力下降。除球差外,两组高阶像差相似(P>.05),微型角膜刀组球差更大(P<.05)。飞秒激光组在术后3个月时,中明视条件下每度12和18周波的对比敏感度值显著提高(P<.05)。与微型角膜刀组相比,飞秒激光组角膜敏感度恢复更快,飞秒激光组术后3个月周边区域角膜敏感度接近正常。
在制瓣过程中,飞秒激光可能优于微型角膜刀。然而,除了角膜感觉恢复更快、球差程度更小以及一些对比敏感度值外,飞秒激光在临床效果上并未显著优于机械微型角膜刀。