Suppr超能文献

通过在线固相萃取的同位素稀释液相色谱-串联质谱法对尿中8-氧代-7,8-二氢-2'-脱氧鸟苷进行临床规模的高通量分析。

Clinical-scale high-throughput analysis of urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine by isotope-dilution liquid chromatography-tandem mass spectrometry with on-line solid-phase extraction.

作者信息

Hu Chiung-Wen, Wang Chien-Jen, Chang Louis W, Chao Mu-Rong

机构信息

Department of Public Health, Chung Shan Medical University, Taichung, Taiwan.

出版信息

Clin Chem. 2006 Jul;52(7):1381-8. doi: 10.1373/clinchem.2005.063735. Epub 2006 May 11.

Abstract

BACKGROUND

Quantification of 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodGuo) in urine or blood is used to assess and monitor oxidative stress in patients. We describe the use of on-line solid-phase extraction (SPE) and isotope-dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) for automated measurement of urinary 8-oxodGuo.

METHODS

Automated purification of urine was accomplished with a switching valve and an Inertsil ODS-3 column. After the addition of 15N5-labeled 8-oxodGuo as an internal standard, urine samples were analyzed within 10 min without sample purification. This method was applied to measure urinary 8-oxodGuo in a group of healthy persons (32 regular smokers and 35 nonsmokers). Urinary cotinine was also assayed by an isotope-dilution LC-MS/MS method.

RESULTS

The lower limit of detection was 5.7 ng/L on column (2.0 fmol). Inter- and intraday imprecision (CV) was < 5.0%. Mean recovery of 8-oxodGuo in urine was 99%-102%. Mean (SD) urinary concentrations of 8-oxodGuo in smokers [7.26 (3.14) microg/g creatinine] were significantly higher than those in nonsmokers [4.69 (1.70) microg/g creatinine; P < 0.005]. Urinary concentrations of 8-oxodGuo were significantly correlated with concentrations of cotinine in smokers (P < 0.05).

CONCLUSIONS

This on-line SPE LC-MS/MS method is sufficiently sensitive, precise, and rapid to provide high-throughput direct analysis of urinary 8-oxodGuo without compromising quality and validation criteria. This method could be applicable for use in daily clinical practice for assessing oxidative stress in patients.

摘要

背景

尿液或血液中8-氧代-7,8-二氢-2'-脱氧鸟苷(8-氧代脱氧鸟苷,8-oxodGuo)的定量分析用于评估和监测患者的氧化应激。我们描述了使用在线固相萃取(SPE)和同位素稀释液相色谱-串联质谱(LC-MS/MS)自动测定尿中8-oxodGuo的方法。

方法

使用切换阀和Inertsil ODS-3柱实现尿液的自动纯化。加入15N5标记的8-oxodGuo作为内标后,无需样品纯化即可在10分钟内分析尿样。该方法用于测量一组健康人(32名经常吸烟者和35名不吸烟者)尿中的8-oxodGuo。尿可替宁也采用同位素稀释LC-MS/MS法进行测定。

结果

柱上检测下限为5.7 ng/L(2.0 fmol)。批间和批内不精密度(CV)<5.0%。尿中8-oxodGuo的平均回收率为99%-102%。吸烟者尿中8-oxodGuo的平均(SD)浓度[7.26(3.14)μg/g肌酐]显著高于不吸烟者[4.69(1.70)μg/g肌酐;P<0.005]。吸烟者尿中8-oxodGuo的浓度与可替宁浓度显著相关(P<0.05)。

结论

这种在线SPE LC-MS/MS方法足够灵敏、精确和快速,能够在不影响质量和验证标准的情况下对尿中8-oxodGuo进行高通量直接分析。该方法可应用于日常临床实践中评估患者的氧化应激。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验