A semianalytic model to extract differential linear scattering coefficients of breast tissue from energy dispersive x-ray diffraction measurements.

作者信息

LeClair Robert J, Boileau Michel M, Wang Yinkun

机构信息

Department of Physics and Astronomy, Laurentian University, 935 Ramsey Lake Road, Sudbury, Ontario, P3E 2C6, Canada.

出版信息

Med Phys. 2006 Apr;33(4):959-67. doi: 10.1118/1.2170616.

DOI:10.1118/1.2170616
PMID:16696472
Abstract

The goal of this work is to develop a technique to measure the x-ray diffraction signals of breast biopsy specimens. A biomedical x-ray diffraction technology capable of measuring such signals may prove to be of diagnostic use to the medical field. Energy dispersive x-ray diffraction measurements coupled with a semianalytical model were used to extract the differential linear scattering coefficients [mus(x)] of breast tissues on absolute scales. The coefficients describe the probabilities of scatter events occuring per unit length of tissue per unit solid angle of detection. They are a function of the momentum transfer argument, x=sin(theta/2)/X, where theta=scatter angle and lambda=incident wavelength. The technique was validated by using a 3 mm diameter 50 kV polychromatic x-ray beam incident on a 5 mm diameter 5 mm thick sample of water. Water was used because good x-ray diffraction data are available in the literature. The scatter profiles from 6 degrees to 15 degrees in increments of 1 degrees were measured with a 3 mm x 3 mm x 2 mm thick cadmium zinc telluride detector. A 2 mm diameter Pb aperture was placed on top of the detector. The target to detector distance was 29 cm and the duration of each measurement was 10 min. Ensemble averages of the results compare well with the gold standard data of A. H. Narten ["X-ray diffraction data on liquid water in the temperature range 4 degrees C-200 degrees C," ORNL Report No. 4578 (1970)]. An average 7.68% difference for which most of the discrepancies can be attributed to the background noise at low angles was obtained. The preliminary measurements of breast tissue are also encouraging.

摘要

相似文献

1
A semianalytic model to extract differential linear scattering coefficients of breast tissue from energy dispersive x-ray diffraction measurements.
Med Phys. 2006 Apr;33(4):959-67. doi: 10.1118/1.2170616.
2
WAXS fat subtraction model to estimate differential linear scattering coefficients of fatless breast tissue: phantom materials evaluation.用于估计无脂肪乳腺组织微分线性散射系数的小角X射线散射脂肪减法模型:体模材料评估
Med Phys. 2014 May;41(5):053501. doi: 10.1118/1.4870982.
3
Optimum momentum transfer arguments for x-ray forward scatter imaging.
Med Phys. 2002 Dec;29(12):2881-90. doi: 10.1118/1.1522749.
4
X-ray scattering in full-field digital mammography.全视野数字乳腺摄影中的X射线散射
Med Phys. 2003 Jul;30(7):1864-73. doi: 10.1118/1.1584160.
5
A method to estimate the fractional fat volume within a ROI of a breast biopsy for WAXS applications: animal tissue evaluation.一种用于WAXS应用的估计乳房活检ROI内脂肪体积分数的方法:动物组织评估。
Med Phys. 2014 Nov;41(11):113501. doi: 10.1118/1.4897384.
6
Correlation of energy dispersive diffraction signatures and microCT of small breast tissue samples with pathological analysis.小乳腺组织样本的能量色散衍射特征与显微CT成像结果和病理分析的相关性
Phys Med Biol. 2007 Oct 21;52(20):6151-64. doi: 10.1088/0031-9155/52/20/005. Epub 2007 Oct 1.
7
Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations.使用蒙特卡罗模拟对千伏锥形束CT图像中的散射线进行表征。
Med Phys. 2006 Nov;33(11):4320-9. doi: 10.1118/1.2358324.
8
Algorithmic scatter correction in dual-energy digital mammography.双能数字乳腺成像中的算法散射校正。
Med Phys. 2013 Nov;40(11):111919. doi: 10.1118/1.4826173.
9
High-resolution CT by diffraction-enhanced x-ray imaging: mapping of breast tissue samples and comparison with their histo-pathology.基于衍射增强X射线成像的高分辨率CT:乳腺组织样本的成像及其与组织病理学的比较
Phys Med Biol. 2007 Apr 21;52(8):2197-211. doi: 10.1088/0031-9155/52/8/011. Epub 2007 Mar 29.
10
Scatter radiation intensities around a clinical digital breast tomosynthesis unit and the impact on radiation shielding considerations.临床数字乳腺断层合成设备周围的散射辐射强度及其对辐射防护考量的影响。
Med Phys. 2016 Mar;43(3):1096-110. doi: 10.1118/1.4940352.

引用本文的文献

1
Model predictions for the wide-angle x-ray scatter signals of healthy and malignant breast duct biopsies.健康和恶性乳腺导管活检的广角X射线散射信号的模型预测。
J Med Imaging (Bellingham). 2015 Oct;2(4):043502. doi: 10.1117/1.JMI.2.4.043502. Epub 2015 Oct 23.