Suppr超能文献

活体肾供体评估:三维16层CT的准确性

Evaluation of living renal donors: accuracy of three-dimensional 16-section CT.

作者信息

Rastogi Neeraj, Sahani Dushyant V, Blake Michael A, Ko Dicken C, Mueller Peter R

机构信息

Department of Radiology, Massachusetts General Hospital, 55 Fruit St, White 270, Boston, MA 02114, USA.

出版信息

Radiology. 2006 Jul;240(1):136-44. doi: 10.1148/radiol.2401050780. Epub 2006 May 23.

Abstract

PURPOSE

To retrospectively assess the sensitivity and specificity of three-dimensional (3D) 16-section computed tomography (CT) in the evaluation of vessels, pelvicalyceal system, and ureters in living renal donors, with surgical findings as the reference standard.

MATERIALS AND METHODS

This was a HIPAA-compliant study. Institutional review board approval was obtained for the review of subjects' medical records and data analysis, with waiver of informed consent. Forty-six renal donors (18 men, 28 women; mean age, 42 years) were examined with 16-section CT. Two blinded reviewers independently studied renal vascular and urographic anatomy of each donor CT scans by fist using 3D images alone, then transverse images alone, and finally transverse and 3D data set. Image quality, degree of diagnostic confidence, and time used for review were recorded. Sensitivity and specificity were calculated.

RESULTS

For 3D images, transverse images, and transverse in conjunction with 3D data sets, the respective sensitivity and specificity of CT in evaluation of accessory arteries by reviewer 1 were 100% and 100%, 89% and 100%, and 100% and 100%, and those by reviewer 2 were 89% and 97%, 89% and 100%, and 89% and 100%; the respective sensitivity and specificity in evaluation of venous anomalies by reviewer 1 were 100% and 98%, 100% and 98%, and 100% and 98%, and those by reviewer 2 were 100% and 98%, 100% and 95%, and 100% and 98%. For focused comprehensive assessment of renal donors with 3D scans alone, a reviewer on average (average of reviewers 1 and 2) used 2.4 minutes per scan, demonstrated full confidence in 93%, and rated the quality as excellent in 76%.

CONCLUSION

For focused assessment of renal vascular and urographic anatomy, review of 3D data set alone provides high sensitivity and specificity with regard to findings seen at surgery.

摘要

目的

以手术结果作为参考标准,回顾性评估三维(3D)16层计算机断层扫描(CT)在评估活体肾供体血管、肾盂肾盏系统和输尿管方面的敏感性和特异性。

材料与方法

本研究符合健康保险流通与责任法案(HIPAA)。经机构审查委员会批准,对受试者的病历进行审查和数据分析,并免除知情同意。46例肾供体(18例男性,28例女性;平均年龄42岁)接受了16层CT检查。两名盲法阅片者首先单独使用3D图像,然后单独使用横断图像,最后使用横断图像和3D数据集,分别独立研究每个供体CT扫描的肾血管和尿路造影解剖结构。记录图像质量、诊断置信度和阅片时间。计算敏感性和特异性。

结果

对于3D图像、横断图像以及横断图像与3D数据集结合的情况,阅片者1对副肾动脉评估的CT敏感性和特异性分别为100%和100%、89%和100%、100%和100%,阅片者2分别为89%和97%、89%和100%、89%和100%;阅片者1对静脉异常评估的敏感性和特异性分别为100%和98%、100%和98%、100%和98%,阅片者2分别为100%和98%、100%和95%、100%和98%。仅使用3D扫描对肾供体进行重点全面评估时,一名阅片者(阅片者1和阅片者2的平均值)平均每次扫描用时2.4分钟,93%表现出完全置信,76%将质量评为优秀。

结论

对于肾血管和尿路造影解剖结构的重点评估,仅审查3D数据集对手术所见具有较高的敏感性和特异性。