• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

The biomechanics of point contact-dynamic compression plate and its effects on bone perfusion.

作者信息

Zhao Yu-feng, Li Qi-hong, Gu Zu-chao, Wang Ai-min

机构信息

Trauma Division II, Daping Hospital, Third Military Medical University, Chongqing 400042, China.

出版信息

Chin J Traumatol. 2006 Jun;9(3):161-7.

PMID:16723074
Abstract

OBJECTIVE

To compare the mechanical properties of point contact-dynamic compression plate (PC-DCP) and its effects on cortical bone perfusion with that of dynamic compression plates (DCP) in goat tibiae.

METHODS

Twenty pairs of matched fresh goat tibiae were used. A transverse fracture model was established. The fractures with a 3mm interspace between the fracture ends were subject to fixations with the DCPs and the PC-DCPs respectively, then the four-points bending tests and the torsion tests were conducted to compare the mechanical properties of the PC-DCP with that of DCP. Another 13 sexually mature goats underwent fixations with the DCPs and the PC-DCPs, respectively, at the mid-shafts of the intact bilateral tibiae. Ischemic zones were observed at four time points (1 day, 2, 6, and 12 weeks after operation) using disulphine blue staining technique.

RESULTS

There were no significant differences in mechanical properties, such as bend- and torsion-resistance, between the DCPs and the PC-DCPs. One day, 2, and 6 weeks after operation, on the side of DCP fixation, outer cortical bone ischemia under the plate persisted, and this condition did not reverse until 12 weeks after operation. However, on the side of PC-DCP fixation, cortical bone ischemia occurred only in the periphery of the screw holes and at the contact sites of the PC NUTs 1 day after operation, and it disappeared at 2 weeks after operation.

CONCLUSIONS

The PC-DCP has similar biomechanical properties of the DCP, but is less detrimental to local bone blood circulation than the conventional plates.

摘要

相似文献

1
The biomechanics of point contact-dynamic compression plate and its effects on bone perfusion.
Chin J Traumatol. 2006 Jun;9(3):161-7.
2
Interface contact profiles of a novel locking plate and its effect on fracture healing in goat.
Chin J Traumatol. 2010 Aug 1;13(4):240-3.
3
Influence of plate design on cortical bone perfusion and fracture healing in canine segmental tibial fractures.钢板设计对犬胫骨节段性骨折皮质骨灌注及骨折愈合的影响
J Orthop Trauma. 1999 Mar-Apr;13(3):178-86. doi: 10.1097/00005131-199903000-00005.
4
A mechanical comparison of the dynamic compression plate, limited contact-dynamic compression plate, and point contact fixator.
J Orthop Trauma. 1995 Feb;9(1):17-22. doi: 10.1097/00005131-199502000-00003.
5
Cortical bone perfusion in plated fractured sheep tibiae.钢板固定的绵羊胫骨骨折处的皮质骨灌注情况
J Orthop Res. 1995 Sep;13(5):715-24. doi: 10.1002/jor.1100130511.
6
Experimental study and clinical observation of minimum-contact plate in long bone fracture.长骨骨折微创接骨板的实验研究与临床观察
Chin J Traumatol. 2005 Apr;8(2):105-10.
7
A biomechanical evaluation of different plates for fixation of canine radial osteotomies.不同接骨板用于犬桡骨截骨固定的生物力学评估
J Trauma. 1998 Jan;44(1):193-7. doi: 10.1097/00005373-199801000-00028.
8
Biomechanical study of a unilocking T-plate system for prophylactic internal fixation of the radial osteocutaneous donor site using the sheep tibia model.羊胫骨模型中用于预防性内固定桡骨骨皮瓣供区的解锁 T 板系统的生物力学研究。
Oral Oncol. 2011 Apr;47(4):268-73. doi: 10.1016/j.oraloncology.2011.02.004.
9
Effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical properties of cortical bone after fracture.不锈钢和钛质低接触动力加压接骨板应用对骨折后皮质骨血管分布及力学性能的影响
J Orthop Trauma. 1997 Oct;11(7):490-5. doi: 10.1097/00005131-199710000-00006.
10
Biomechanical comparison of straight DCP and helical plates for fixation of transverse and oblique bone fractures.用于固定横行和斜行骨折的直形动力加压接骨板与螺旋接骨板的生物力学比较
Acta Bioeng Biomech. 2014;16(4):67-74.