An analytical high-performance liquid chromatography (HPLC)-fluorescence method for indirect measuring of whey protein in casein coprecipitate and milk powder was developed. Samples were hydrolyzed with HCl, and cysteyl residues were derivatized with 3,3'-dithiodipropionic acid and 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate. The cysteine content was used to calculate the percentage of whey protein in commercial samples with use of European Union Regulation cysteine reference values in both casein and whey protein. Method validation studies were performed for caseinates and milk powder, and results indicate that the present HPLC approach can be applied as a fast method with a standard deviation of repeatability between 3.3 and 9.5%. Applicability was studied by analysis of 40 commercial caseinate samples, and all complied to European legislation with a content of whey protein not exceeding 5%. Finally, an approach used to estimate the cysteine amount in pure casein by comparison of calculated and experimental values questions the generally accepted cysteine reference value in casein, which is most likely an overestimation.
建立了一种用于间接测定酪蛋白共沉淀物和奶粉中乳清蛋白的分析型高效液相色谱(HPLC)-荧光法。样品用盐酸水解,半胱氨酰残基用3,3'-二硫代二丙酸和6-氨基喹啉-N-羟基琥珀酰亚胺基甲酸酯衍生化。利用欧盟法规中酪蛋白和乳清蛋白的半胱氨酸参考值,通过半胱氨酸含量计算商业样品中乳清蛋白的百分比。对酪蛋白酸盐和奶粉进行了方法验证研究,结果表明,目前的HPLC方法可作为一种快速方法应用,重复性标准偏差在3.3%至9.5%之间。通过分析40个商业酪蛋白酸盐样品研究了其适用性,所有样品均符合欧洲法规,乳清蛋白含量不超过5%。最后,通过比较计算值和实验值来估计纯酪蛋白中半胱氨酸含量的方法对酪蛋白中普遍接受的半胱氨酸参考值提出了质疑,该参考值很可能被高估了。