Pino Esteban, Ohno-Machado Lucila, Wiechmann Eduardo, Curtis Dorothy
Decision System Group, Brigham and Women's Hosp., Harvard Med. Sch., Boston, MA, USA.
AMIA Annu Symp Proc. 2005;2005:604-8.
Brigham & Women's Hospital is designing a wireless monitoring system for patients on the waiting area of the Emergency Department. A real-time ECG algorithm is required to monitor and alert changes in patients that have not yet been admitted to the Emergency Room. For this purpose, three simple algorithms are compared in terms of processing time, beat detection accuracy and heart rate (HR) estimation. Varying amounts of noise were added to records from the MIT-BIH Arrhythmia Database [1] to mimic expected waiting room conditions. Some recommendations regarding selection of an algorithm and further processing of HR series are presented.
布莱根妇女医院正在为急诊科候诊区的患者设计一种无线监测系统。需要一种实时心电图算法来监测并提醒尚未进入急诊室的患者的变化。为此,从处理时间、心跳检测准确率和心率(HR)估计方面对三种简单算法进行了比较。向麻省理工学院-贝斯以色列女执事医疗中心心律失常数据库[1]的记录中添加了不同量的噪声,以模拟预期的候诊室情况。针对算法选择和心率序列的进一步处理提出了一些建议。