• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Inter-laboratory comparison of NO2 and SO2 generated by dynamic dilution system under laboratory conditions: a technical discussion.

作者信息

Khaparde V V

机构信息

Air Pollution Control Division, National Environmental Engineering Research Institute, Nagpur, India.

出版信息

Environ Monit Assess. 2006 May;116(1-3):217-31. doi: 10.1007/s10661-006-7393-z.

DOI:10.1007/s10661-006-7393-z
PMID:16779591
Abstract

A workshop on analytical quality control (AQC) of ambient air quality measurement methods for nitrogen dioxide (NO(2)) and sulphur dioxide (SO(2)) was conducted by Central Pollution Control Board (CPCB) for officials involved in National Ambient Air Quality Monitoring (NAAQM) in India. Concentrations of NO(2) and SO(2) were generated by dynamic dilution system under laboratory conditions at low and high levels and measured using static dilution system and wet chemical methods laid down by CPCB under section 16(2)(h) of the air act 1981. CPCB provided the measured values as reference values for comparing the means obtained by the officials participated from thirteen organizations. A tolerance limit of +/-15% of the reference values was specified to accept the results. Generated concentrations, which were unknown to the participants, were measured using gaseous sampling assembly (Envirotech APM 411, New Delhi, India), and wet chemical methods laid down by CPCB i.e. the same methodology which is used by the organizations to generate the data of NO(2) and SO(2) in ambient air. Simultaneously, concentrations were checked by CPCB using automatic analyzers as a check on reference concentration. It is observed that results of automatic analyzers for NO(2) and SO(2) were within a tolerance of +/-5% with %RSD below 3. On the other hand, results of most of the participants showed variability in the measurements with %RSD ranging between +/-0.8 and +/-88.6 and exceedences of means from the tolerance limit with bias ranging between 1.4 and -59%. To check the cause of high variability in the measurements obtained under identical conditions, duplicate sampling was performed by one of the participants for SO(2) at low concentration level. In this study, results of wet chemical methods, automatic analyzers and results of duplicate sampling are analysed statistically to assess the cause of high variability in the measurements. Analysis of t-test and analysis of variance (ANOVA) showed highly significant results for NO(2) and SO(2) at high concentration levels (alpha 0.05) and for SO(2) at both the levels (alpha 0.01) respectively indicating some bias is existing either in the sampling or in analytical technique. Duplicate sampling performed to check precision in parallel measurements showed high %RSD indicating the presence of systematic error in sampling technique as the same calibration factor (CF) was used to measure the concentration of duplicate samples. Statistical analysis of flow rates of duplicate sampling showed that the sampling assembly could not maintain the constant flow rate within the +/-10% with that measured at the start of the sampling. This resulted in high %RSD and deviation from the reference values for the results of most of the participants, even after accepting +/-15% tolerance limit. There is a need to improve and evaluate this gaseous sample collection device under laboratory conditions to generate reliable database of NO(2) and SO(2) in ambient air.

摘要

相似文献

1
Inter-laboratory comparison of NO2 and SO2 generated by dynamic dilution system under laboratory conditions: a technical discussion.
Environ Monit Assess. 2006 May;116(1-3):217-31. doi: 10.1007/s10661-006-7393-z.
2
Street-level concentrations of suspended particulate matter (SPM), nitrogen dioxide (NO2) and sulphur dioxide (SO2) in Pune City.浦那市街道层面的悬浮颗粒物(SPM)、二氧化氮(NO₂)和二氧化硫(SO₂)浓度。
J Environ Sci Eng. 2004 Apr;46(2):143-50.
3
Performances and application of a passive sampling method for the simultaneous determination of nitrogen dioxide and sulfur dioxide in ambient air.一种用于同时测定环境空气中二氧化氮和二氧化硫的被动采样方法的性能及应用
Environ Monit Assess. 2002 Nov;79(3):301-15. doi: 10.1023/a:1020205230396.
4
Emissions variability processor (EMVAP): design, evaluation, and application.排放变异性处理器(EMVAP):设计、评估与应用
J Air Waste Manag Assoc. 2014 Dec;64(12):1390-402. doi: 10.1080/10962247.2014.956159.
5
The impact of the congestion charging scheme on air quality in London. Part 1. Emissions modeling and analysis of air pollution measurements.拥堵收费计划对伦敦空气质量的影响。第1部分。排放建模与空气污染测量分析。
Res Rep Health Eff Inst. 2011 Apr(155):5-71.
6
Effect of reagent (dye) addition in wet chemical method of sulfur dioxide determination in ambient air.试剂(染料)添加对环境空气中二氧化硫测定的湿化学法的影响。
Environ Monit Assess. 2006 Sep;120(1-3):461-76. doi: 10.1007/s10661-005-9073-9. Epub 2006 Jun 2.
7
Part 5. Public health and air pollution in Asia (PAPA): a combined analysis of four studies of air pollution and mortality.第五部分. 亚洲的公共卫生与空气污染(PAPA):四项空气污染与死亡率研究的综合分析
Res Rep Health Eff Inst. 2010 Nov(154):377-418.
8
Part 2. Time-series study on air pollution and mortality in Delhi.第二部分:德里空气污染与死亡率的时间序列研究。
Res Rep Health Eff Inst. 2011 Mar(157):47-74.
9
Part 2. Association of daily mortality with ambient air pollution, and effect modification by extremely high temperature in Wuhan, China.第二部分. 中国武汉每日死亡率与环境空气污染的关联以及极高温度的效应修正
Res Rep Health Eff Inst. 2010 Nov(154):91-217.
10
Forecasts using Box-Jenkins models for the ambient air quality data of Delhi City.使用Box-Jenkins模型对德里市环境空气质量数据进行预测。
Environ Monit Assess. 2009 Oct;157(1-4):105-12. doi: 10.1007/s10661-008-0520-2. Epub 2008 Sep 26.

本文引用的文献

1
Quality control in air sampling pump calibration.
Am Ind Hyg Assoc J. 1979 Mar;40(3):249-53. doi: 10.1080/15298667991429561.