Oh Kwang-Jun, Imrie Susana, Hwang Kathy, Ramachandran Ravi, Shegog Mychelle, Goodman Stuart B
Department of Orthopedic Surgery, Konkuk University Medical Center, Seoul, Korea.
Clin Orthop Relat Res. 2006 Jun;447:85-91. doi: 10.1097/01.blo.0000194670.77849.ea.
We report the outcome of a prospective consecutive series of 52 primary total hip arthroplasties using the miniature porous-coated Anatomic Medullary Locking stem in patients with small anatomic proportions because of hip dysplasia or juvenile chronic arthritis. The mean age of the patients at the time of surgery was 28.7 years (range 14-56 years). The average body weight and height of the patients were 51.8 kg (range 38.5-78.3 kg) and 157.1 cm (range 142.2-183 cm), respectively. The stem was cementless in 40 hips and cemented in 12 hips because of poor bone stock. A cementless acetabular cup with screw was used in all hips. The average followup was 7.1 years (range, 3-15.6 years). The Harris hip scores improved from an average of 31.2 points (range, 3.1-68.8 points)preoperatively to 82.8 points (range, 61.1-96.6 points) at latest followup. Three of 12 (25%) cemented and two of 40 (5%) cementless stem were revised. Four of seven 42-44-mm cups were revised. The miniature Anatomic Medullary Locking cementless femoral stem provides a satisfactory outcome in patients with small anatomic proportions. However, wear and osteolysis with the use of a small cementless polyethylene liner remain challenges.
我们报告了对52例因髋关节发育不良或幼年慢性关节炎导致解剖比例较小的患者,使用微型多孔涂层解剖型髓内锁定柄进行初次全髋关节置换术的前瞻性连续系列研究结果。手术时患者的平均年龄为28.7岁(范围14 - 56岁)。患者的平均体重和身高分别为51.8 kg(范围38.5 - 78.3 kg)和157.1 cm(范围142.2 - 183 cm)。由于骨量不佳,40髋采用非骨水泥柄,12髋采用骨水泥柄。所有髋关节均使用带螺钉的非骨水泥髋臼杯。平均随访7.1年(范围3 - 15.6年)。Harris髋关节评分从术前平均31.2分(范围3.1 - 68.8分)提高到末次随访时的82.8分(范围61.1 - 96.6分)。12例骨水泥柄中有3例(25%)翻修,40例非骨水泥柄中有2例(5%)翻修。7个42 - 44 mm的髋臼杯中有4个翻修。微型解剖型髓内锁定非骨水泥股骨柄在解剖比例较小的患者中提供了令人满意的结果。然而,使用小型非骨水泥聚乙烯内衬的磨损和骨溶解仍然是挑战。