Viola Arpad, Major Tibor, Julow Jeno
Doctoral School, Semmelweis University, 1085 Budapest, Hungary.
Radiat Res. 2006 Jun;165(6):695-702. doi: 10.1667/RR3529.1.
The goal of this study was to make a comparison between stereotactic brachytherapy implants and linear accelerator-based radiosurgery of brain tumors with respect to physical dose distributions and radiobiological efficacy. Twenty-four treatment plans made for irradiation of brain tumors with low-dose-rate (125)I brachytherapy and multiple-arc LINAC-based radiosurgery were analyzed. Using the dose-volume histograms and the linear-quadratic model, the brachytherapy doses were compared to the brachytherapy-equivalent LINAC radiosurgery doses with respect to the predicted late effects of radiation on normal brain tissue. To characterize the conformity and homogeneity of dose distributions, the conformal index, external volume index, and relative homogeneity index were calculated for each dose plan and the mean values were compared. The average tumor volume was 5.6 cm(3) (range: 0.1-19.3 cm(3)). At low doses, the calculated radiobiological late effect on normal tissue was equivalent for external-beam and brachytherapy dose delivery. For brachytherapy at doses greater than 30 Gy, the calculated equivalent dose to normal tissues was less than for external-beam radiosurgery. However, the dose-calculated homogeneity was better for the LINAC radiosurgery, with a mean relative homogeneity index of 0.62 compared to the calculated value of 0.19 for the brachytherapy (P=0.0002). These results are only predictions based on calculations concerning normal tissue tolerance. More data and research are needed to understand the clinical relevance of these findings.
本研究的目的是在物理剂量分布和放射生物学疗效方面,对脑肿瘤的立体定向近距离放射治疗植入物和基于直线加速器的放射外科进行比较。分析了针对低剂量率(125)I近距离放射治疗和基于多弧直线加速器的放射外科的脑肿瘤照射制定的24个治疗计划。使用剂量体积直方图和线性二次模型,就辐射对正常脑组织的预测晚期效应而言,将近距离放射治疗剂量与近距离放射治疗等效的直线加速器放射外科剂量进行比较。为了表征剂量分布的适形性和均匀性,计算每个剂量计划的适形指数、外部体积指数和相对均匀性指数,并比较平均值。平均肿瘤体积为5.6 cm³(范围:0.1 - 19.3 cm³)。在低剂量时,计算得出的对外周组织的放射生物学晚期效应对于外照射和近距离放射治疗剂量传递是等效的。对于剂量大于30 Gy的近距离放射治疗,计算得出的对正常组织的等效剂量低于外照射放射外科。然而,直线加速器放射外科的剂量计算均匀性更好,平均相对均匀性指数为0.62,而近距离放射治疗的计算值为0.19(P = 0.0002)。这些结果仅是基于关于正常组织耐受性计算的预测。需要更多数据和研究来了解这些发现的临床相关性。