Botelho Michael G, Leung Katherine C M, Ng Hyden, Chan Kingsley
J Am Dent Assoc. 2006 Jun;137(6):783-8. doi: 10.14219/jada.archive.2006.0290.
The authors conducted a study to examine the clinical performance of two-unit cantilevered resin-bonded fixed partial dentures (RBFPDs) that were inserted at The Prince Philip Dental Hospital, University of Hong Kong.
The authors recalled patients who had received two-unit cantilevered RBFPDs at least 24 months before the recall examination. The authors recorded the following data: patient's sex and age, operator's experience, prosthesis cementation date, endodontic treatment if performed, bone support, tooth mobility, the presence of shim-stock contacts on the abutment or pontic in intercuspal position, and the presence of aproximal axial contacts adjacent to the prosthesis. They also recorded the date of any debonding with subsequent treatment. They asked the patients qualitative questions about their prostheses.
A total of 269 prostheses were placed in 214 patients and had a mean service life of 51.7 months +/- 19.5 months standard deviation, with a range of 13.2 to 141.6 months. Of 14 failed prostheses, 12 debonded, resulting in a success rate of 94.8 percent and clinical retention rate of 95.5 percent. No discernable rotation or drifting of the abutments was apparent in any of the prostheses. Overall patient satisfaction with RBFPDs was good, with an average assessment score of 8.5.
The authors observed a 95.5 percent clinical retention rate of 269 two-unit RBFPDs, with no apparent drifting of the abutments. Longer-term follow-up studies are required.
Two-unit RBFPDs are conservative and clinically retentive prostheses in the short to medium term.
作者进行了一项研究,以检查在香港大学菲腊牙科医院植入的双单位悬臂式树脂粘结固定局部义齿(RBFPD)的临床性能。
作者召回了在召回检查前至少24个月接受双单位悬臂式RBFPD的患者。作者记录了以下数据:患者的性别和年龄、操作者的经验、假体粘结日期、是否进行过牙髓治疗、骨支持情况、牙齿松动度、在牙尖交错位时基牙或桥体上是否存在薄垫片接触,以及假体相邻处是否存在近中轴向接触。他们还记录了任何脱粘及后续治疗的日期。他们向患者询问了有关其假体的定性问题。
共为214名患者植入了269个假体,平均使用寿命为51.7个月±19.5个月标准差,范围为13.2至141.6个月。在14个失败的假体中,12个发生脱粘,成功率为94.8%,临床固位率为95.5%。在任何假体中均未观察到基牙有明显的旋转或漂移。患者对RBFPD的总体满意度良好,平均评估得分为8.5。
作者观察到269个双单位RBFPD的临床固位率为95.5%,基牙无明显漂移。需要进行长期随访研究。
双单位RBFPD在短期至中期是保守且临床固位良好的假体。