骨定量超声与骨折之间的关系:一项荟萃分析。

Relationship between bone quantitative ultrasound and fractures: a meta-analysis.

作者信息

Marín Fernando, González-Macías Jesús, Díez-Pérez Adolfo, Palma Silvia, Delgado-Rodríguez Miguel

机构信息

Lilly Research Center, Erl Wood Manor, Windlesham, United Kingdom.

出版信息

J Bone Miner Res. 2006 Jul;21(7):1126-35. doi: 10.1359/jbmr.060417.

Abstract

UNLABELLED

The relationship between bone QUS and fracture risk was estimated in a systematic review of data from 14 prospective studies of 47,300 individuals and 2350 incident fractures. In older women, low QUS values were associated with overall fracture risk, low-trauma fractures, and with hip, forearm, and humerus fractures separately.

INTRODUCTION

Bone quantitative ultrasound (QUS) has emerged as a promising technique to evaluate bone status. The aim of this study was to determine the association between measurements of QUS with the risk of fracture.

MATERIALS AND METHODS

A meta-analysis of prospective cohort studies published between 1985 and June 2005 with a baseline measurement of QUS and subsequent follow-up for fractures was carried out. Fourteen separate study populations, consisting of about 47,300 individuals (85.4% women), with about 124,000 person-years of observation and over 2350 fractures, including 653 hip, 529 forearm, and 386 humeral fractures, were analyzed. The main outcome measure was the estimated relative risk of fracture for a decrease in bone QUS parameters of 1 SD below sex- and age-adjusted mean in women.

RESULTS

Eleven studies evaluated QUS at the heel, with patella and phalanx (two studies each) and distal radius (one study) being scarcely used. There was not significant heterogeneity among the studies included in the review. Relative risk estimates (95% CI) for overall fractures were 1.55 (1.35-1.78) for each SD decrease in broadband ultrasound attenuation (BUA), 1.63 (1.37-1.93) for speed of sound (SOS), and 1.74 (1.39-2.17) for QUS index/stiffness index (QUI/SI). Risk estimates were similar or slightly higher for hip fractures and low-energy trauma fractures. Humeral and forearm/wrist fractures were also related with lower QUS values.

CONCLUSIONS

Measurements of bone QUS are significantly associated with nonspinal fracture risk in older women in a similar degree to DXA. QUS may be a valid alternative to evaluate fracture risk in situations where DXA is not accessible.

摘要

未标注

通过对来自14项前瞻性研究的数据进行系统评价,这些研究涉及47300名个体和2350例新发骨折,估计了骨定量超声(QUS)与骨折风险之间的关系。在老年女性中,低QUS值与总体骨折风险、低创伤骨折以及分别与髋部、前臂和肱骨骨折相关。

引言

骨定量超声(QUS)已成为一种有前景的评估骨状态的技术。本研究的目的是确定QUS测量值与骨折风险之间的关联。

材料与方法

对1985年至2005年6月发表的前瞻性队列研究进行荟萃分析,这些研究有QUS的基线测量值以及随后的骨折随访。分析了14个独立的研究人群,约47300名个体(85.4%为女性),有大约124000人年的观察期和超过2350例骨折,包括653例髋部骨折、529例前臂骨折和386例肱骨骨折。主要结局指标是女性骨QUS参数降低至低于性别和年龄校正均值1个标准差时骨折的估计相对风险。

结果

11项研究评估了足跟的QUS,很少使用髌骨和指骨(各两项研究)以及桡骨远端(一项研究)。纳入综述的研究之间不存在显著异质性。对于总体骨折,每降低1个标准差的宽带超声衰减(BUA),相对风险估计值(95%可信区间)为1.55(1.35 - 1.78),声速(SOS)为1.63(1.37 - 1.93),QUS指数/硬度指数(QUI/SI)为1.74(1.39 - 2.17)。髋部骨折和低能量创伤骨折的风险估计值相似或略高。肱骨和前臂/腕部骨折也与较低的QUS值相关。

结论

在老年女性中,骨QUS测量值与非脊柱骨折风险显著相关,程度与双能X线吸收法(DXA)相似。在无法获得DXA的情况下,QUS可能是评估骨折风险有效的替代方法。