Thorne Jennifer E, Anhalt Grant J, Jabs Douglas A, de la Cruz Zenaida, Green W Richard
Department of Ophthalmology, Johns Hopkins University School of Medicine, Baltimore, Maryland 21205, USA.
Ophthalmology. 2006 Sep;113(9):1651-6. doi: 10.1016/j.ophtha.2006.03.048. Epub 2006 Jul 7.
To evaluate the role of electron microscopy (EM) for the diagnosis of ocular mucous membrane pemphigoid (MMP) among patients with cicatrizing conjunctivitis.
Retrospective case series.
One hundred twenty-eight patients with cicatrizing conjunctivitis referred for the evaluation of possible ocular MMP between January 1985 and February 2002 who underwent conjunctival biopsy and evaluation with EM and direct immunofluorescent (DIF) techniques.
The diagnosis of each patient was based on DIF techniques. The reproducibility of EM readings was measured by assessing intraobserver and interobserver variability. The diagnosis from EM was compared to the DIF diagnosis from the same patient to evaluate the validity of the EM diagnosis.
Sensitivity, specificity, positive predictive value, and negative predictive value of EM for diagnosing ocular MMP.
One hundred twenty-six of 128 conjunctival biopsies were available for evaluation of EM findings. The percent agreement between 2 readings from the same observer was 92%, and the percent agreement between 2 independent observers was 78%. The sensitivity and specificity of EM for the diagnosis of ocular MMP were 51% and 72%, respectively. The positive predictive value of EM for the diagnosis of ocular MMP was 49%.
The reproducibility of EM findings was good as indicated by high percent agreement for both intraobserver and interobserver measurements. However, the sensitivity, specificity, and positive predictive value of EM for the diagnosis of ocular MMP was low. It seems that EM has limited usefulness in the diagnosis of ocular MMP.
评估电子显微镜检查(EM)在瘢痕性结膜炎患者眼部类天疱疮(MMP)诊断中的作用。
回顾性病例系列研究。
1985年1月至2002年2月期间,128例因疑似眼部MMP而转诊进行评估的瘢痕性结膜炎患者,均接受了结膜活检,并采用EM和直接免疫荧光(DIF)技术进行评估。
每位患者的诊断基于DIF技术。通过评估观察者内和观察者间的变异性来测量EM读数的可重复性。将EM诊断结果与同一患者的DIF诊断结果进行比较,以评估EM诊断的有效性。
EM诊断眼部MMP的敏感性、特异性、阳性预测值和阴性预测值。
128例结膜活检中有126例可用于评估EM检查结果。同一观察者两次读数之间的一致性百分比为92%,两名独立观察者之间的一致性百分比为78%。EM诊断眼部MMP的敏感性和特异性分别为51%和72%。EM诊断眼部MMP的阳性预测值为49%。
观察者内和观察者间测量的高一致性百分比表明,EM检查结果的可重复性良好。然而,EM诊断眼部MMP的敏感性、特异性和阳性预测值较低。看来EM在眼部MMP的诊断中作用有限。