Thelwall Peter E, Shepherd Timothy M, Stanisz Greg J, Blackband Stephen J
Department of Neuroscience, McKnight Brain Institute, University of Florida, Gainesville, Florida, USA.
Magn Reson Med. 2006 Aug;56(2):282-9. doi: 10.1002/mrm.20962.
Ex vivo biological sample imaging can complement in vivo MRI studies. Since ex vivo studies are typically performed at room temperature, and samples are frequently preserved by fixation, it is important to understand how environmental and chemical changes dictated by ex vivo studies alter the physical and MR properties of a sample. Diffusion and relaxation time measurements were used to assess the effects of temperature change and aldehyde fixation on the biophysical and MR properties of a model biological tissue comprised of erythrocyte ghosts suspended in buffer or agarose gel. Sample temperature was varied between 10 degrees C and 37 degrees C. Diffusion MRI data were analyzed with a biophysically appropriate two-compartment exchange model. Temperature change resulted in a complex alteration of water diffusion properties due to the compartmental nature of tissues and alteration in membrane permeability. Formaldehyde, Karnovsky's solution, and glutaraldehyde all caused statistically significant changes to the biophysical and MR properties of the samples. Fixation caused large decreases in water proton T2, which was restored to near prefixation values by washing free fixative from the samples. Water membrane permeability was also significantly altered by fixation. This study demonstrates that relating in vivo MR data to chemically fixed ex vivo data requires an understanding of the effects of sample preparation.
离体生物样本成像可以补充活体磁共振成像(MRI)研究。由于离体研究通常在室温下进行,且样本经常通过固定来保存,因此了解离体研究所导致的环境和化学变化如何改变样本的物理和磁共振特性非常重要。扩散和弛豫时间测量被用于评估温度变化和醛固定对由悬浮在缓冲液或琼脂糖凝胶中的红细胞膜组成的模型生物组织的生物物理和磁共振特性的影响。样本温度在10摄氏度至37摄氏度之间变化。扩散MRI数据用生物物理上合适的双室交换模型进行分析。由于组织的隔室性质和膜通透性的改变,温度变化导致水扩散特性的复杂改变。甲醛、卡诺夫斯基溶液和戊二醛均对样本的生物物理和磁共振特性产生了统计学上显著的变化。固定导致水质子T2大幅下降,通过从样本中洗去游离固定剂,T2恢复到接近固定前的值。固定也显著改变了水的膜通透性。这项研究表明,将活体MR数据与化学固定的离体数据相关联需要了解样本制备的影响。