Addo K K, Dan-Dzide M, Yeboah-Manu D, Owusu-Darko K, Caulley P, Minamikawa M, Bonsu F, Lienhardt C, Akpedonu P, Ofori-Adjei D
Department of Bacteriology, Noguchi Memorial Institute for Medical Research, Legon, Ghana.
Int J Tuberc Lung Dis. 2006 Jul;10(7):812-7.
Greater Accra region, Ghana.
To establish a pilot quality assurance (QA) system in sputum smear microscopy and to evaluate its impact.
Quarterly supporting visits were paid to participating laboratories between 2000 and 2002. Fifteen examined slides were selected randomly from each laboratory during the visits and blindly re-assessed. Feedback was given promptly to the various laboratories. Training and stakeholder workshops were organised whenever necessary.
General improvements in smear preparation and staining as well as the reading ability of the laboratory personnel included in the study were observed. The average marks for specimen quality, staining ability, smear cleanness, thickness, size and evenness increased from 64%, 79%, 69%, 46%, 67% and 60% in the last quarter of 2000 to 81%, 90%, 86%, 79%, 80% and 74%, respectively, 24 months after the establishment of the QA system. Within the same period, the rate of false-positives and -negatives decreased from respectively 14.8% and 20.5% to 0%, and agreements in positivity grade increased from 74% to 95%. The performance of the participating laboratories in keeping the laboratory registers up to date also improved.
The QA system needs to be extended to the rest of the country.
加纳大阿克拉地区。
在痰涂片显微镜检查中建立试点质量保证(QA)系统并评估其影响。
在2000年至2002年期间,每季度对参与的实验室进行支持性访问。访问期间,从每个实验室随机选取15张已检查的玻片进行盲法重新评估。及时向各个实验室提供反馈。必要时组织培训和利益相关者研讨会。
观察到涂片制备、染色以及研究中涉及的实验室人员的阅片能力普遍有所提高。质量保证系统建立24个月后,标本质量、染色能力、涂片清洁度、厚度、大小和均匀度的平均分数分别从2000年最后一个季度的64%、79%、69%、46%、67%和60%提高到81%、90%、86%、79%、80%和74%。在同一时期,假阳性和假阴性率分别从1