Simultaneous identification of optical isomers (D and L) of methamphetamine (MAMP), amphetamine (AMP), para(p)-hydroxy(OH)-MAMP, and para(p)-hydroxy(OH)-AMP in rat urine was attempted by high-performance liquid chromatography (HPLC). They were determined as benzoyl derivatives. After administration of D- or L-isomer (15 mg/kg), only D- or L-isomers of the above mentioned metabolites were found in rat urine. In rats administered racemic MAMP (15 mg/kg), each percent dose of L-isomers of MAMP or AMP excreted at four collection times up to 24 h was less than that of the D-isomer (L/D less than 1.00), but the doses of L-isomers of p-OH-MAMP and p-OH-AMP excreted were higher than those of D-isomers (L/D greater than 1.00). Simultaneous analysis within 36 minutes showed good peak resolution. The L/D ratio for each metabolite decreased with time. The total percent doses of D- or L-isomer excreted by 24 hours were about 50% of the administered dose, 23.70 +/- 1.45% for the D-isomer, 25.70 +/- 1.54% for the L-isomers. The total L/D ratio was 1.08 +/- 0.03. These results indicated that Wistar rats have no chiral isomerization enzyme of MAMP, and show stereoselective metabolism of DL-MAMP. In the optical isomer analysis of 11 MAMP powder samples and 28 human urine specimens obtained from Japanese abusers, only D-MAMP was detected in the powder, and D-MAMP and D-AMP were detected in urine, respectively. This suggested that humans have no chiral isomerization enzyme of D-MAMP.

摘要

尝试采用高效液相色谱法(HPLC)同时鉴定大鼠尿液中甲基苯丙胺(MAMP)、苯丙胺(AMP)、对(p)-羟基(OH)-MAMP和对(p)-羟基(OH)-AMP的光学异构体(D型和L型)。它们被测定为苯甲酰衍生物。给予D型或L型异构体(15mg/kg)后,在大鼠尿液中仅发现上述代谢物的D型或L型异构体。给予消旋MAMP(15mg/kg)的大鼠中,在长达24小时的四个采集时间点排泄的MAMP或AMP的L型异构体的各百分比剂量均低于D型异构体(L/D小于1.00),但排泄的对羟基MAMP和对羟基AMP的L型异构体剂量高于D型异构体(L/D大于1.00)。36分钟内的同时分析显示出良好的峰分辨率。每种代谢物的L/D比值随时间降低。24小时排泄的D型或L型异构体的总百分比剂量约为给药剂量的50%,D型异构体为23.70±1.45%,L型异构体为25.70±1.54%。总L/D比值为1.08±0.03。这些结果表明,Wistar大鼠没有MAMP的手性异构酶,并显示出DL-MAMP的立体选择性代谢。在对11份MAMP粉末样品和28份从日本滥用者处获得的人类尿液标本进行的光学异构体分析中,在粉末中仅检测到D-MAMP,在尿液中分别检测到D-MAMP和D-AMP。这表明人类没有D-MAMP的手性异构酶。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验