Suppr超能文献

采用贝克曼库尔特酶联免疫吸附测定法(ELISA)和DSL酶联免疫吸附测定法测定血清抗苗勒管激素:在辅助生殖技术(ART)中的比较及相关性

Measurement of serum anti-Müllerian hormone by Beckman Coulter ELISA and DSL ELISA: comparison and relevance in assisted reproduction technology (ART).

作者信息

Fréour Thomas, Mirallié Sophie, Bach-Ngohou Kalyane, Denis Marc, Barrière Paul, Masson Damien

机构信息

Department of Human Reproduction, CHU Nantes, France.

出版信息

Clin Chim Acta. 2007 Jan;375(1-2):162-4. doi: 10.1016/j.cca.2006.06.013. Epub 2006 Jun 20.

Abstract

BACKGROUND

Numerous studies have evocated the clinical usefulness of serum AMH levels as a predictor of ovarian response and pregnancy in assisted reproductive technology cycles. Nevertheless, the analysis of the literature shows a great dispersion in serum AMH concentrations obtained with different methods from almost comparable populations.

METHODS

We compared two commercial immunoassays (AMH Beckman Coulter ELISA and AMH DSL ELISA) and we evaluated the AMH levels in serum as a prognosis value for ovarian response and pregnancy in assisted reproductive technology cycles.

RESULTS

We found a close linear relationship between the two methods but AMH levels were almost 4.6-fold lower with the DSL kit than with the Beckman Coulter kit. We found a significant and positive correlation between the number of mature ovocytes inseminated and AMH levels obtained with the two methods. Whatever the ELISA used, we found no significant difference between AMH level of pregnancy and non pregnancy groups. Indeed, using the Beckman Coulter method, all pregnant patients had serum AMH levels over 1.4 microg/L. Conversely, no cut-off value can be found for the DSL kit.

CONCLUSION

Our results show clearly for the first time that AMH results are method dependent even if the correlation obtained between the two methods remained excellent. The Beckman Coulter AMH ELISA should produce clinical agreement when used for prognosis purposes on patients undergoing assisted reproduction.

摘要

背景

众多研究已证实血清抗苗勒管激素(AMH)水平作为辅助生殖技术周期中卵巢反应和妊娠预测指标的临床实用性。然而,文献分析显示,在几乎可比的人群中,使用不同方法获得的血清AMH浓度存在很大差异。

方法

我们比较了两种商业免疫测定法(贝克曼库尔特AMH酶联免疫吸附测定法和DSL AMH酶联免疫吸附测定法),并评估了血清中的AMH水平作为辅助生殖技术周期中卵巢反应和妊娠的预后价值。

结果

我们发现两种方法之间存在密切的线性关系,但使用DSL试剂盒测得的AMH水平比贝克曼库尔特试剂盒测得的低近4.6倍。我们发现受精的成熟卵母细胞数量与两种方法测得的AMH水平之间存在显著正相关。无论使用哪种酶联免疫吸附测定法,我们发现妊娠组和非妊娠组的AMH水平均无显著差异。实际上,使用贝克曼库尔特方法时,所有妊娠患者的血清AMH水平均超过1.4μg/L。相反,DSL试剂盒未发现临界值。

结论

我们的结果首次明确表明,即使两种方法之间的相关性仍然很好,但AMH检测结果仍取决于检测方法。当用于辅助生殖患者的预后评估时,贝克曼库尔特AMH酶联免疫吸附测定法应能产生临床一致性结果。