Suppr超能文献

Measurement of the internal diameter of plastic tubes from projection MR images using a model-based least-squares fit approach.

作者信息

Tzeng Yang-Sheng, Mansour Joey, Handler Zachary, Gereige Jessica, Shah Niral, Zhou Xin, Albert Mitchell

机构信息

Brigham and Women's Hospital, Boston, Massachusetts 02115, USA.

出版信息

Med Phys. 2006 Jun;33(6):1643-53. doi: 10.1118/1.2194427.

Abstract

Hyperpolarized (HP) 3He MRI is an emerging tool in the diagnosis and evaluation of pulmonary diseases involving bronchoconstriction, such as asthma. Previously, airway diameters from dynamic HP 3He MR images of the lung were assessed manually and subjectively, and were thus prone to uncertainties associated with human error and partial volume effects. A model-based algorithm capable of fully utilizing pixel intensity profile information and attaining subpixel resolution has been developed to measure surrogate airway diameters from HP 3He MR static projection images of plastic tubes. This goal was achieved by fitting ideal pixel intensity profiles for various diameter (6.4 to 19.1 mm) circular tubes to actual pixel intensity data. A phantom was constructed from plastic tubes of various diameters connected in series and filled with water mixed with contrast agent. Projection MR images were then taken of the phantom. The favorable performance of the model-based algorithm compared to manual assessment demonstrates the viability of our approach. The manual and algorithm approaches yielded diameter measurements that generally stayed within 1 x the pixel dimension. However, inconsistency of the manual approach can be observed from the larger standard deviations of its measured values. The method was then extended to HP 3He MRI, producing encouraging results at tube diameters characteristic of airways beyond the second generation, thereby justifying their application to lung airway imaging and measurement. Potential obstacles when measuring airway diameters using this method are discussed.

摘要

相似文献

5
Merging parametric active contours within homogeneous image regions for MRI-based lung segmentation.
IEEE Trans Med Imaging. 2003 Feb;22(2):189-99. doi: 10.1109/TMI.2002.808354.
7
Proton and hyperpolarized helium magnetic resonance imaging of radiation-induced lung injury in rats.
Int J Radiat Oncol Biol Phys. 2004 Apr 1;58(5):1562-9. doi: 10.1016/j.ijrobp.2003.12.010.
8
Elucidation of structure-function relationships in the lung: contributions from hyperpolarized 3helium MRI.
Clin Physiol Funct Imaging. 2002 Nov;22(6):361-9. doi: 10.1046/j.1475-097x.2002.00444.x.
9
Hyperpolarized 3He MRI and 81mKr SPECT in chronic obstructive pulmonary disease.
Eur J Nucl Med Mol Imaging. 2005 Apr;32(4):448-57. doi: 10.1007/s00259-004-1691-x. Epub 2004 Nov 20.
10
An evaluation of pulmonary atelectasis and its re-expansion: hyperpolarized 3He MRI in the Yorkshire pig.
Acad Radiol. 2003 Nov;10(11):1283-90. doi: 10.1016/s1076-6332(03)00469-0.

本文引用的文献

2
Evaluation of airway wall thickness and air trapping by HRCT in asymptomatic asthma.
Eur Respir J. 2003 Dec;22(6):965-71. doi: 10.1183/09031936.03.00085302.
3
Dynamic 3He imaging for quantification of regional lung ventilation parameters.
Magn Reson Med. 2003 Oct;50(4):777-83. doi: 10.1002/mrm.10590.
6
Dynamic radial projection MRI of inhaled hyperpolarized 3He gas.
Magn Reson Med. 2003 Jun;49(6):991-7. doi: 10.1002/mrm.10477.
7
How does airway inflammation modulate asthmatic airway constriction? An antigen challenge study.
J Appl Physiol (1985). 2003 Aug;95(2):873-82; discussion 863. doi: 10.1152/japplphysiol.00075.2003. Epub 2003 Apr 18.
8
Distal airways in humans: dynamic hyperpolarized 3He MR imaging--feasibility.
Radiology. 2003 May;227(2):575-9. doi: 10.1148/radiol.2272012146. Epub 2003 Mar 27.
9
Measurement of regional lung function in rats using hyperpolarized 3helium dynamic MRI.
Magn Reson Med. 2003 Jan;49(1):78-88. doi: 10.1002/mrm.10336.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验