Iinuma I, Uenoyama K, Sakaguchi T
Department of Ophthalmology, Hospital of Wakayama Medical College, Japan.
Am J Ophthalmol. 1966 May;61(5 Pt 1):853-9.
The intraocular pressure responses in living rabbit and enucleated human eyes during tonography, suction-cup and bulbar pressure tests were continuously recorded by closed electric manometry. The tonography tests in rabbits produced an initial rapid rise in pressure, followed by a slight decline during tonography and a sharp drop to a level lower than the initial pressure as soon as tonography was discontinued; recovery to the initial pressure level was gradual. Increasing the plunger weights made the responses more marked. Enucleated human eyes showed similar results except, of course, there was no recovery to the initial pressure level. Similar pressure responses were produced in the suction cup and bulbar pressure tests. Our data showed that the manometric curves in living rabbit and enucleated human eyes during compression are of the same type.
通过闭合式电子测压法持续记录了在眼压描记、吸盘和眼球压力测试过程中,活体兔眼和摘除的人眼的眼压反应。兔眼压描记测试时,压力最初迅速上升,随后在眼压描记过程中略有下降,一旦停止眼压描记,压力会急剧下降至低于初始压力的水平;压力逐渐恢复到初始压力水平。增加柱塞重量会使反应更明显。摘除的人眼显示出类似结果,当然,不会恢复到初始压力水平。吸盘和眼球压力测试也产生了类似的压力反应。我们的数据表明,活体兔眼和摘除的人眼在受压过程中的测压曲线类型相同。