PURPOSE

To determine the biocompatibility of a new wireless intraocular pressure (IOP) transducer (WIT) in rabbit eyes and to correlate its measurements with other pressure-measuring devices.

METHODS

The WIT is a ring-shaped intraocular device that allows wireless IOP measurements through radiofrequency. It was implanted into six eyes of New Zealand White rabbits after extracapsular lens extraction. A sham rabbit eye with no transducer implanted was used as a control. The animals were observed and examined by microscopy at various intervals up to 25 months after surgery. IOP was measured at various intervals by pneumotonometry, tonometry, WIT, and manometry. The data from the various devices were compared and analyzed for reproducibility. Two eyes were enucleated at 5.5 and 20 months after implantation and analyzed by histology.

RESULTS

The WIT appears to be well tolerated in the rabbit eye, with no evidence of significant inflammation or scar formation by microscopic in vivo examination. Histology did not reveal intraocular inflammation or membrane formation. Repeated IOP measurements with pneumotonometry, tonometry, and the WIT resulted in SDs of 2.70 mm Hg, 3.35 mm Hg, and 0.81 mm Hg, respectively. The concordance between the WIT and direct manometry measurements was high. A downward drift in IOP measured by the WIT was noted in three rabbits, necessitating recalibration.

CONCLUSIONS

The WIT is well tolerated by the rabbit eye. Its measurements are reproducible and in close concordance with manometry. A downward IOP drift warrants further investigation.

摘要

目的

确定新型无线眼压(IOP)传感器(WIT)在兔眼内的生物相容性,并将其测量值与其他压力测量设备进行相关比较。

方法

WIT 是一种环形眼内设备,通过射频实现无线 IOP 测量。在白内障囊外摘出术后,将其植入新西兰白兔的六只眼中。一只未植入传感器的假兔眼作为对照。术后不同时间间隔,通过显微镜观察和检查来监测动物。通过气动眼压计、眼压计、WIT 和眼压计在不同时间间隔测量 IOP。对各种设备的数据进行比较和分析,以评估其重现性。在植入后 5.5 个月和 20 个月时,两只眼被摘出并进行组织学分析。

结果

WIT 在兔眼中似乎具有良好的耐受性,通过活体显微镜检查未发现明显的炎症或瘢痕形成。组织学检查未发现眼内炎症或膜形成。气动眼压计、眼压计和 WIT 重复测量 IOP 的标准差分别为 2.70mmHg、3.35mmHg 和 0.81mmHg。WIT 与直接眼压计测量值之间具有高度一致性。在三只兔子中,WIT 测量的眼压出现下降漂移,需要重新校准。

结论

WIT 在兔眼中具有良好的耐受性。其测量值具有可重复性,并且与眼压计高度一致。眼压的下降漂移需要进一步研究。