This article reports on the electric network frequency criterion as a means of assessing the integrity of digital audio/video evidence and forensic IT and telecommunication analysis. A brief description is given to different ENF types and phenomena that determine ENF variations. In most situations, to reach a non-authenticity opinion, the visual inspection of spectrograms and comparison with an ENF database are enough. A more detailed investigation, in the time domain, requires short time windows measurements and analyses. The stability of the ENF over geographical distances has been established by comparison of synchronized recordings made at different locations on the same network. Real cases are presented, in which the ENF criterion was used to investigate audio and video files created with secret surveillance systems, a digitized audio/video recording and a TV broadcasted reportage. By applying the ENF Criterion in forensic audio/video analysis, one can determine whether and where a digital recording has been edited, establish whether it was made at the time claimed, and identify the time and date of the registering operation.
本文报道了电网频率标准作为评估数字音频/视频证据以及法医信息技术和电信分析完整性的一种手段。简要描述了不同的电网频率类型以及决定电网频率变化的现象。在大多数情况下,要得出非真实性的结论,对频谱图进行目视检查并与电网频率数据库进行比较就足够了。在时域进行更详细的调查需要短时间窗口测量和分析。通过比较在同一网络不同位置进行的同步记录,已确定了电网频率在地理距离上的稳定性。文中给出了实际案例,其中电网频率标准被用于调查通过秘密监视系统创建的音频和视频文件、数字化音频/视频记录以及电视广播报道。通过在法医音频/视频分析中应用电网频率标准,可以确定数字记录是否以及在何处被编辑,确定它是否在声称的时间制作,并识别记录操作的时间和日期。