Ebo D G, Sainte-Laudy J, Bridts C H, Mertens C H, Hagendorens M M, Schuerwegh A J, De Clerck L S, Stevens W J
Department of Immunology, Allergology, Rheumatology, University Antwerp (UA), Antwerpen, Belgium.
Allergy. 2006 Sep;61(9):1028-39. doi: 10.1111/j.1398-9995.2006.01039.x.
Physicians predominantly rely upon quantification of serum-specific immunoglobulin E (IgE) and/or skin test to confirm clinically suspected IgE-mediated allergy. However, for various reasons, identification of the offending allergen(s) and potentially cross-reactive structures is not always straightforward. Flow-assisted allergy diagnosis relies upon quantification of alterations in the expression of particular basophilic activation markers. Actually, upon challenge with a specific allergen, basophils not only secrete quantifiable bioactive mediators but also upregulate the expression of different markers which can be detected efficiently by flow cytometry using specific monoclonal antibodies. Currently, the technique has been applied in the investigation of IgE-mediated allergy caused by classical inhalant allergens, food, Hevea latex, hymenoptera venoms and drugs. It is also appreciated; the technique proves valuable in the diagnosis of non-IgE-mediated (anaphylactoid) reactions such drug hypersensitivity and the detection of autoantibodies in certain forms of chronic urticaria. This review will not address immunologic features, characteristics and general pitfalls of flow-assisted analysis of in vitro-activated basophils as summarized elsewhere. After a recapitulation of the principles and some specific technical issues of flow-assisted analysis of in vitro-activated basophils, we principally focus on the current clinical and research applications of the basophil activation tests. Personal experience of both research groups is provided, where appropriate. Finally, a viewpoint on how the field might evolve in the following years is provided.
医生主要依靠血清特异性免疫球蛋白E(IgE)定量检测和/或皮肤试验来确诊临床疑似的IgE介导的过敏反应。然而,由于各种原因,确定致病过敏原和潜在的交叉反应结构并非总是易事。流式细胞术辅助过敏诊断依赖于特定嗜碱性粒细胞活化标志物表达变化的定量检测。实际上,在用特定过敏原激发后,嗜碱性粒细胞不仅会分泌可定量的生物活性介质,还会上调不同标志物的表达,这些标志物可通过使用特异性单克隆抗体的流式细胞术有效检测。目前,该技术已应用于由经典吸入性过敏原、食物、橡胶乳胶、膜翅目毒液和药物引起的IgE介导的过敏反应的研究。此外,该技术在诊断非IgE介导的(类过敏)反应(如药物超敏反应)以及检测某些形式慢性荨麻疹中的自身抗体方面也被证明具有价值。本综述不会讨论体外活化嗜碱性粒细胞流式细胞术辅助分析的免疫学特征、特点和一般陷阱,这些内容已在其他地方进行了总结。在简述体外活化嗜碱性粒细胞流式细胞术辅助分析的原理和一些特定技术问题后,我们主要关注嗜碱性粒细胞活化试验的当前临床和研究应用。在适当的地方提供了两个研究小组的个人经验。最后,对该领域在未来几年可能如何发展提出了一种观点。