PURPOSE

To investigate whether the visualization of axillary sentinel nodes (SN) in the lymphoscintigraphy (LS) can be enhanced by adjusting the amount of radioactivity in accordance with the patient's body mass index (BMI).

MATERIAL AND METHODS

Group I consisted of 356 consecutive breast cancer patients who underwent LS and SN biopsy after a single, intratumoral radioactive tracer injection with a median dose of 92 MBq. In group II (178 consecutive patients), the dose of the tracer was adjusted according to BMI; 80, 100, or 140 MBq.

RESULTS

The visualization rate of axillary SN was 86% in group I and 83% in group II (P = 0.303). In patients with BMI >30 with visualized axillary SN, the median number of SN was 1 (1-4) in group I and 3 (1-7) in group II (P = 0.002).

CONCLUSION

Adjusting the tracer dose in accordance with patient BMI did not enhance the visualization rate of axillary SN in LS.