Suppr超能文献

1.5T与3T 1H磁共振波谱在人脑肿瘤中的比较。

Comparison of 1.5T and 3T 1H MR spectroscopy for human brain tumors.

作者信息

Kim Ji-hoon, Chang Kee-Hyun, Na Dong Gyu, Song In Chan, Kim Seung Ja, Kwon Bae Ju, Han Moon Hee

机构信息

Department of Radiology, Seoul Municipal Boramae Hospital, Seoul National University Hospital, Seoul, Korea.

出版信息

Korean J Radiol. 2006 Jul-Sep;7(3):156-61. doi: 10.3348/kjr.2006.7.3.156.

Abstract

OBJECTIVE

We wanted to estimate the practical improvements of 3T proton MR spectroscopy ((1)H MRS) as compared with 1.5T (1)H MRS for the evaluation of human brain tumors.

MATERIALS AND METHODS

Single voxel (1)H MRS was performed at both 1.5T and 3T in 13 patients suffering with brain tumors. Using the same data acquisition parameters at both field strengths, the (1)H MRS spectra were obtained with a short echo time (TE) (35 msec) and an intermediate TE (144 msec) with the voxel size ranging from 2.0 cm(3) to 8.7 cm(3). The signal to noise ratios (SNRs) of the metabolites (myoinositol [MI], choline compounds [Cho], creatine /phosphocreatine [Cr], N-acetyl-aspartate [NAA], lipid and lactate [LL]) and the metabolite ratios of MI/Cr, Cho/Cr, Cho/NAA and LL/Cr were compared at both TEs between the two field strengths in each brain tumor. The degrees of spectral resolution between the Cho and Cr peaks were qualitatively compared between the two field strengths in each brain tumor.

RESULTS

The SNRs of the metabolites at 3T demonstrated 49-73% increase at a short TE (p < 0.01) and only 2-12% increase at an intermediate TE (p > 0.05) compared with those of 1.5T. The SNR of inverted lactate at an intermediate TE decreased down to 49% with poorer inversion at 3T (p < 0.05). There was no significant difference in the metabolite ratios between the two field strengths. The degrees of the spectral resolution at 3T were slightly superior to those of 1.5T at a short TE.

CONCLUSION

As compared with 1.5T, 3T 1H MRS demonstrated 49-73% SNR increase in the cerebral metabolites and slightly superior spectral resolution only at a short TE, but little at an intermediate TE, in the brain tumors. There was no significant difference in the metabolite ratios between the two field strengths.

摘要

目的

我们想要评估与1.5T质子磁共振波谱((1)H MRS)相比,3T (1)H MRS在评估人脑肿瘤方面的实际改进情况。

材料与方法

对13例脑肿瘤患者分别在1.5T和3T场强下进行单体素质子磁共振波谱检查。在两个场强下使用相同的数据采集参数,以短回波时间(TE)(35毫秒)和中等TE(144毫秒)获取(1)H MRS谱,体素大小范围为2.0立方厘米至8.7立方厘米。比较每个脑肿瘤在两个场强下两种TE时代谢物(肌醇[MI]、胆碱化合物[Cho]、肌酸/磷酸肌酸[Cr]、N-乙酰天门冬氨酸[NAA]、脂质和乳酸[LL])的信噪比(SNR)以及MI/Cr、Cho/Cr、Cho/NAA和LL/Cr的代谢物比率。定性比较每个脑肿瘤在两个场强下Cho和Cr峰之间的光谱分辨率程度。

结果

与1.5T相比,3T时短TE下代谢物的SNR提高了49 - 73%(p < 0.01),中等TE下仅提高了2 - 12%(p > 0.05)。中等TE下反转乳酸的SNR在3T时降至49%,反转效果较差(p < 0.05)。两个场强下代谢物比率无显著差异。3T时短TE下的光谱分辨率程度略优于1.5T。

结论

与1.5T相比,3T (1)H MRS在脑肿瘤中,仅在短TE时脑代谢物的SNR提高了49 - 73%,光谱分辨率略优,中等TE时改善不大。两个场强下代谢物比率无显著差异。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/31ac/2667596/53d22c7acf0a/kjr-7-156-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验