A clinical neutron activation instrument has been developed for in vivo elemental analysis. Utilizing the prompt-capture gamma ray technique, simultaneous total body (TB) measurements of primarily Ca, but also Cl, N, C, and H are routinely performed. This paper describes a technique for the measurement of TBCa (g) that relies on the use of TBCl as an internal standard. The method has been tested with four anthropomorphic phantoms covering a range of body habitus. The mean discrepancy between the measured and known Ca contents was 3.6%. The technique has been applied to two patient groups, and encouraging results were obtained.

摘要

已开发出一种用于体内元素分析的临床中子活化仪器。利用瞬发俘获伽马射线技术,常规进行主要针对钙,但也包括氯、氮、碳和氢的全身(TB)同时测量。本文描述了一种依赖于使用TBCl作为内标的TBCa(克)测量技术。该方法已在覆盖一系列体型的四个人体模型上进行了测试。测量的钙含量与已知钙含量之间的平均差异为3.6%。该技术已应用于两个患者组,并获得了令人鼓舞的结果。