• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

The presumptive detection of benzene in water in the presence of phenol with an active membrane-UV photo-ionisation differential mobility spectrometer.

作者信息

Kanu Abu B, Thomas C L Paul

机构信息

Department of Chemistry, Washington State University, Pullman, Washington 99164-4630, USA.

出版信息

Analyst. 2006 Sep;131(9):990-9. doi: 10.1039/b607077a. Epub 2006 Aug 7.

DOI:10.1039/b607077a
PMID:17047798
Abstract

Studies with a new technique, active membrane-differential mobility spectrometry, with aqueous standards of benzene and phenol are described. The atmospheric pressure photo-ionisation chemistries of benzene and phenol in the presence of oxygen are similar in that benzene forms phenol radicals that subsequently react to yield diphenylether and 4-phenoxyphenol products. Further phenol sequesters charge from benzene ions leading to a significant loss of sensitivity. This is an important consideration in the development of screening techniques for the presence of benzene in environmental water samples. This challenge was addressed by including a pre-separation stage prior to photo-ionisation, and a 10 cm long polydimethylsiloxane active membrane inlet using nitrogen as a carrier gas was used to sample, concentrate and deliver low resolution separations to the 10.6 eV UV-ionisation region of a differential mobility spectrometer. Acetone was also proposed as a charge carrier for the UV photo-ionisation source; to promote phenol protonation and inhibit charge sequestration from benzene. The responses of the system to aqueous standards of benzene and phenol with and without acetone doping at 10.2 mg m(-3) were evaluated and four to five-fold increases in sensitivity were obtained with acetone doping. With a sampling time of 60 s and a total measurement cycle of 180 s it was possible to obtain quantitative responses to single standards over the concentration range 6 to 177 microg cm(-3) with linear correlations with R(2) values ranging from 0.97 to 0.99. The effects of the heating rate of the membrane and the dispersion field strength of the differential mobility spectrometer on sensitivity and the differentiation of benzene from phenol responses were optimised, leading to a configuration where a voltage heating programme of 4.75 V s(-1) was applied to a 124 microm stainless steel wire heating element within the active membrane, and a dispersion field strength of 22 kV cm(-1) was used to test a mixture of benzene (14 microg cm(-3)) and phenol (6 microg cm(-3)) in water. The presence of benzene was identified through the presence of a peak corresponding to a benzene response, V(C) = -9 V FWHM = 1 V, that followed the thermal desorption profile of benzene.

摘要

相似文献

1
The presumptive detection of benzene in water in the presence of phenol with an active membrane-UV photo-ionisation differential mobility spectrometer.
Analyst. 2006 Sep;131(9):990-9. doi: 10.1039/b607077a. Epub 2006 Aug 7.
2
Programmable gate delayed ion mobility spectrometry-mass spectrometry: a study with low concentrations of dipropylene-glycol-monomethyl-ether in air.可编程门延迟离子迁移谱-质谱联用:空气中低浓度二丙二醇单甲醚的研究
Analyst. 2005 Aug;130(8):1155-61. doi: 10.1039/b502215k. Epub 2005 Jun 27.
3
Increasing analytical space in gas chromatography-differential mobility spectrometry with dispersion field amplitude programming.通过色散场幅度编程增加气相色谱-差分离子迁移谱中的分析空间。
J Chromatogr A. 2007 Nov 30;1173(1-2):129-38. doi: 10.1016/j.chroma.2007.09.082. Epub 2007 Oct 11.
4
Phenol production in benzene/air plasmas at atmospheric pressure. Role of radical and ionic routes.常压下苯/空气等离子体中苯酚的生成。自由基和离子途径的作用。
J Phys Chem A. 2006 Jun 29;110(25):7841-7. doi: 10.1021/jp062406p.
5
Fast quantitative characterisation of differential mobility responses.
Analyst. 2004 Mar;129(3):198-204. doi: 10.1039/b310760d. Epub 2004 Jan 20.
6
Optimisation of secondary electrospray ionisation (SESI) for the trace determination of gas-phase volatile organic compounds.优化二次电喷雾离子化(SESI)用于痕量气相挥发性有机化合物的测定。
Analyst. 2010 Feb;135(2):306-14. doi: 10.1039/b918899a. Epub 2010 Jan 7.
7
Miniature differential mobility spectrometry using atmospheric pressure photoionization.采用大气压光电离的微型差分离子迁移谱法。
Anal Chem. 2006 Jul 1;78(13):4553-63. doi: 10.1021/ac052213i.
8
Atmospheric pressure photoionization mechanisms. 2. The case of benzene and toluene.大气压光电离机制。2. 苯和甲苯的情况。
Rapid Commun Mass Spectrom. 2003;17(21):2423-9. doi: 10.1002/rcm.1208.
9
Analysis of benzene, toluene, ethylbenzene, xylenes and n-aldehydes in melted snow water via solid-phase dynamic extraction combined with gas chromatography/mass spectrometry.通过固相动态萃取结合气相色谱/质谱法分析融雪水中的苯、甲苯、乙苯、二甲苯和正醛。
J Chromatogr A. 2008 Jan 18;1178(1-2):178-86. doi: 10.1016/j.chroma.2007.11.025. Epub 2007 Nov 17.
10
Optimising cell temperature and dispersion field strength for the screening for putrescine and cadaverine with thermal desorption-gas chromatography-differential mobility spectrometry.优化细胞温度和分散场强,用于通过热脱附-气相色谱-差分迁移谱法筛选腐胺和尸胺。
Anal Chim Acta. 2008 Mar 24;611(2):226-32. doi: 10.1016/j.aca.2008.01.083. Epub 2008 Feb 12.