Jiang W P, Huang J, Fang Z X
Department of Cardiology, First Affiliated Hospital, Suzhou Medical College.
Zhonghua Nei Ke Za Zhi. 1990 Nov;29(11):649-52, 701.
Signal-averaged electrocardiograms (SAECGs) were performed in 93 patients with various heart diseases and 20 dogs with experimental acute myocardial infarction. SA-ECGs were recorded with a high-pass bidirectional digital filter Mode FDS which was made by Shanghai Fudan University and Suzhou Medical College. All the patients and dogs were also examined with ART 1200 EPX recorder. Ventricular late potentials (VLPs) were directly recorded from the epicardium with experimental infarction by using composite electrodes and signal averaging system in late stage of coronary ligation. The results showed: VLPs were detected by body surface SA-ECG only in half of the dogs with VLPs detected by the real time mapping on infarction region, but the abnormal SAECGs did reveal the delayed ventricular activity; the data obtained with FDS or ART SA-ECG were similar.
对93例患有各种心脏病的患者和20只患有实验性急性心肌梗死的狗进行了信号平均心电图(SAECGs)检查。SA-ECGs采用由上海复旦大学和苏州医学院制造的高通双向数字滤波器FDS模式进行记录。所有患者和狗也都使用ART 1200 EPX记录仪进行了检查。在冠状动脉结扎后期,通过使用复合电极和信号平均系统,直接从实验性梗死的心外膜记录心室晚电位(VLPs)。结果显示:仅在通过梗死区域实时标测检测到VLPs的狗中,一半的狗通过体表SA-ECG检测到了VLPs,但异常的SAECGs确实显示了心室活动延迟;使用FDS或ART SA-ECG获得的数据相似。