Suppr超能文献

向新生儿提供自由流动的氧气。

Free-flow oxygen delivery to newly born infants.

作者信息

Dawson Jennifer A, Davis Peter G, O'Donnell Colm P F, Omar F Kamlin C, Morley Colin J

机构信息

Division of Newborn Services, The Royal Women's Hospital, Carlton, Victoria, Australia .

出版信息

Arch Dis Child Fetal Neonatal Ed. 2007 Mar;92(2):F132-4. doi: 10.1136/adc.2006.103077. Epub 2006 Nov 1.

Abstract

Resuscitation guidelines recommend administration of free-flow oxygen to newly born infants who breathe but remain cyanosed. Self-inflating resuscitation bags are described as unreliable for this purpose. We measured oxygen concentrations >or=80% delivered through a 240 mL Laerdal self-inflating resuscitation bag and from 5 mm tubing inside a cupped hand.

摘要

复苏指南建议,对于有呼吸但仍有发绀的新生儿给予自由流动的氧气。自充气式复苏袋在这种情况下被认为是不可靠的。我们测量了通过一个240毫升的Laerdal自充气式复苏袋以及从置于杯状手中的5毫米内径的管道输送的氧气浓度≥80%。

相似文献

1
Free-flow oxygen delivery to newly born infants.向新生儿提供自由流动的氧气。
Arch Dis Child Fetal Neonatal Ed. 2007 Mar;92(2):F132-4. doi: 10.1136/adc.2006.103077. Epub 2006 Nov 1.
2
Oxygen delivery using neonatal self-inflating resuscitation bags without a reservoir.使用无储氧袋的新生儿自动充气复苏袋供氧。
Arch Dis Child Fetal Neonatal Ed. 2010 Sep;95(5):F315-9. doi: 10.1136/adc.2009.166462. Epub 2009 Oct 19.
6
A comparison of three neonatal resuscitation devices.三种新生儿复苏设备的比较。
Resuscitation. 2005 Oct;67(1):113-8. doi: 10.1016/j.resuscitation.2005.02.016.
8
Laerdal infant resuscitators are unreliable as free-flow oxygen delivery devices.
Am J Perinatol. 1997 Jul;14(6):347-51. doi: 10.1055/s-2007-994158.

引用本文的文献

1
RECOVER Guidelines: Newborn Resuscitation in Dogs and Cats. Clinical Guidelines.《RECOVER指南:犬猫新生儿复苏。临床指南》
J Vet Emerg Crit Care (San Antonio). 2025 Aug;35 Suppl 1(Suppl 1):S60-S85. doi: 10.1111/vec.70013.

本文引用的文献

4
Oxygen delivery using self-inflating resuscitation bags.使用自动充气复苏袋进行氧气输送。
Pediatr Crit Care Med. 2005 Mar;6(2):125-8. doi: 10.1097/01.PCC.0000154945.05394.A9.
6
The efficacy of noncontact oxygen delivery methods.
Pediatrics. 2002 Nov;110(5):964-7. doi: 10.1542/peds.110.5.964.
7
Laerdal infant resuscitators are unreliable as free-flow oxygen delivery devices.
Am J Perinatol. 1997 Jul;14(6):347-51. doi: 10.1055/s-2007-994158.