PURPOSE

This study was carried out to compare cytometric bead array (CBA) technology with conventional enzyme linked immunosorbent assay (ELISA) for the measurement of both vitreous and serum concentrations of interleukin-8 (IL-8), vascular endothelial growth factor (VEGF), and angiogenin (ANG) in diabetic and non-diabetic patients.

METHODS

Measurement of vitreous and serum concentrations of IL-8, VEGF, and ANG using both ELISA and CBA was performed in 26 probands (13 diabetics and 13 non-diabetic control subjects).

RESULTS

Vitreous and serum concentrations of IL-8, VEGF, and ANG determined by CBA showed a strong correlation with those measured by ELISA. Vitreous levels of IL-8, VEGF, and ANG were significantly higher in diabetics compared to non-diabetic control subjects. No significant correlation between vitreous and serum levels of any of the investigated parameters were found in either diabetics or control individuals.

CONCLUSIONS

The present study is the first to utilize cytometric bead array technology for the measurement of angiogenic factors in the vitreous. Measurements obtained by ELISA and CBA technologies were highly correlated for IL-8, VEGF, and ANG in both vitreous and serum samples. Diabetic individuals showed significant elevation of IL-8, VEGF, and ANG in the vitreous but not in serum samples compared to control subjects. The most striking advantage of the CBA technology is the fact that numerous parameters can be measured in parallel using a comparatively small sample volume. It is therefore more rapid and cost effective than ELISA technology. CBA technology is a new, accurate method to measure IL-8, VEGF, and ANG in the vitreous.

摘要

目的

本研究旨在比较细胞计数珠蛋白阵列(CBA)技术与传统酶联免疫吸附测定(ELISA)法,用于测量糖尿病患者和非糖尿病患者玻璃体液和血清中白细胞介素-8(IL-8)、血管内皮生长因子(VEGF)和血管生成素(ANG)的浓度。

方法

对26名受试者(13名糖尿病患者和13名非糖尿病对照者)使用ELISA和CBA两种方法测量玻璃体液和血清中IL-8、VEGF和ANG的浓度。

结果

CBA法测定的玻璃体液和血清中IL-8、VEGF和ANG的浓度与ELISA法测定的结果显示出强烈的相关性。糖尿病患者玻璃体液中IL-8、VEGF和ANG的水平显著高于非糖尿病对照者。在糖尿病患者或对照个体中,所研究的任何参数的玻璃体液和血清水平之间均未发现显著相关性。

结论

本研究首次利用细胞计数珠蛋白阵列技术测量玻璃体液中的血管生成因子。ELISA和CBA技术在玻璃体液和血清样本中对IL-8、VEGF和ANG的测量结果高度相关。与对照受试者相比,糖尿病个体玻璃体液中IL-8、VEGF和ANG显著升高,但血清样本中未升高。CBA技术最显著的优势在于能够使用相对少量的样本体积同时测量多个参数。因此,它比ELISA技术更快速且更具成本效益。CBA技术是一种测量玻璃体液中IL-8、VEGF和ANG的新的、准确的方法。