Suppr超能文献

采用全心冠状动脉磁共振血管造影术检测冠状动脉狭窄

Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography.

作者信息

Sakuma Hajime, Ichikawa Yasutaka, Chino Shuji, Hirano Tadanori, Makino Katsutoshi, Takeda Kan

机构信息

Department of Radiology, Mie University Hospital, Mie, Japan.

出版信息

J Am Coll Cardiol. 2006 Nov 21;48(10):1946-50. doi: 10.1016/j.jacc.2006.07.055. Epub 2006 Oct 31.

Abstract

OBJECTIVES

We sought to determine the diagnostic performance of whole-heart coronary magnetic resonance (MR) angiography for detecting significant coronary artery disease.

BACKGROUND

The accuracy of whole-heart coronary MR angiography has not been determined in a large number of patients.

METHODS

Three-dimensional coronary MR angiograms covering the entire heart were obtained during free breathing in 131 patients. Images were acquired during a patient-specific time window in the cardiac cycle with minimal motion of the coronary artery. Significant coronary artery disease was defined on X-ray coronary angiography as a diameter reduction of > or =50% in coronary arteries with a reference diameter of > or =2 mm.

RESULTS

The acquisition of MR angiography was completed in 113 (86%) of 131 patients, with an imaging time averaged at 12.9 +/- 4.3 min. On a patient-based analysis, the sensitivity, specificity, positive and negative predictive value, and accuracy of MR angiography were 82% (95% confidence interval [CI] 69% to 91%), 90% (95% CI 79% to 96%), 88% (95% CI 74% to 95%), 86% (95% CI 75% to 93%), and 87% (95% CI 79% to 92%), respectively. These values in the individual segments were 78% (95% CI 68% to 85%), 96% (95% CI 95% to 97%), 69% (95% CI 60% to 77%), 98% (95% CI 96% to 98%), and 94% (95% CI 96% to 96%).

CONCLUSIONS

Whole-heart coronary MR angiography allows for noninvasive detection of significant narrowing in coronary arterial segments with a diameter of > or =2 mm with moderate sensitivity and high specificity.

摘要

目的

我们试图确定全心冠状动脉磁共振(MR)血管造影术检测显著冠状动脉疾病的诊断性能。

背景

全心冠状动脉MR血管造影术的准确性尚未在大量患者中得到确定。

方法

在131例患者自由呼吸期间获取覆盖整个心脏的三维冠状动脉MR血管造影图像。在心动周期中特定于患者的时间窗内采集图像,使冠状动脉运动最小化。X线冠状动脉血管造影术将显著冠状动脉疾病定义为参考直径≥2mm的冠状动脉直径减少≥50%。

结果

131例患者中有113例(86%)完成了MR血管造影采集,平均成像时间为12.9±4.3分钟。基于患者的分析中,MR血管造影术的敏感性、特异性、阳性和阴性预测值以及准确性分别为82%(95%置信区间[CI]69%至91%)、90%(95%CI79%至96%)、88%(95%CI74%至95%)、86%(95%CI75%至93%)和87%(95%CI79%至92%)。各节段的这些值分别为78%(95%CI68%至85%)、96%(95%CI95%至97%)、69%(95%CI60%至77%)、98%(95%CI96%至98%)和94%(95%CI96%至96%)。

结论

全心冠状动脉MR血管造影术能够以中等敏感性和高特异性对直径≥2mm的冠状动脉节段中的显著狭窄进行无创检测。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验