Abstract

Knowledge of forces in the glenohumeral joint is essential for understanding normal and pathologic shoulder function. It forms the basis for performing fracture treatment or joint replacement surgery, for optimizing implant design and fixation and for improving and verifying analytical biomechanical models of the shoulder. An instrumented shoulder implant with telemetric data transmission was developed to measure six components of joint contact forces and moments. A patient with humeral head arthrosis achieved good joint function after its implantation. During the first 7 postoperative months, the contact force remained below 100% BW (percent body weight) for most activities of daily living. It ranged up to 130% BW for arm positions close to the limits of motion or when acting against external resistance. When the patient tried to turn a blocked steering wheel with maximum effort, the force rose to about 150% BW, the highest level observed thus far. Of great interest were the force directions relative to the humerus, especially those in the sagittal plane, which were not greatly influenced by the type of exercise, the arm position or the external resistance. The moments due to friction in the joint reached 5.2 Nm. The friction-induced shift of contact forces relative to the implant head centre ranged up to 6.3mm. These first worldwide in vivo measurements of glenohumeral contact forces are being continued in more patients and for longer postoperative times.

摘要

了解盂肱关节中的力对于理解正常和病理状态下的肩部功能至关重要。它是进行骨折治疗或关节置换手术、优化植入物设计和固定以及改进和验证肩部分析生物力学模型的基础。已开发出一种具有遥测数据传输功能的仪器化肩部植入物,用于测量关节接触力和力矩的六个分量。一名患有肱骨头关节炎的患者在植入后获得了良好的关节功能。在术后的前7个月中,对于大多数日常生活活动,接触力保持在100%体重(BW)以下。当手臂处于接近运动极限的位置或对抗外部阻力时,接触力范围可达130%BW。当患者用最大力气试图转动卡住的方向盘时,力上升到约150%BW,这是迄今为止观察到的最高水平。特别令人感兴趣的是力相对于肱骨的方向,尤其是在矢状面内的方向,这些方向不受运动类型、手臂位置或外部阻力的很大影响。关节中由摩擦产生的力矩达到5.2牛米。接触力相对于植入物头部中心因摩擦而产生的位移范围可达6.3毫米。这些首次在全球范围内对盂肱接触力进行的体内测量正在更多患者中持续进行,并且术后时间更长。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验