Bontus Claas, Koken Peter, Köhler Thomas, Proksa Roland
Philips Research Europe-Hamburg, Sector Medical Imaging Systems, Röntgenstrasse 24-26, D-22 335 Hamburg, Germany.
Phys Med Biol. 2007 Jan 7;52(1):107-20. doi: 10.1088/0031-9155/52/1/008. Epub 2006 Dec 12.
The combination of circular CT with a helical trajectory segment results in a mathematically complete data set. We present a reconstruction algorithm which is mathematically exact and of the filtered back-projection type. The algorithm ensures that only Radon planes which are not covered along the circle are taken into account, when data from the helical segment are back-projected. Therefore, the helical segment contributes only to low-frequency parts of trans-axial slices. Data along the helix can be obtained with a very low acquisition dose.
圆形CT与螺旋轨迹段相结合可得到数学上完整的数据集。我们提出了一种数学上精确的、滤波反投影类型的重建算法。该算法确保在对螺旋段数据进行反投影时,只考虑沿圆周未覆盖的拉东平面。因此,螺旋段仅对横断面切片的低频部分有贡献。沿螺旋线的数据可以用非常低的采集剂量获得。